Arama Sonuçları..
Toplam 251 kayıt bulundu.
Multi-Range Vacuum Gauge MRV 100
Measuring instrument for use in the coarse, fine and high vacuum ranges Can only be used with sensor Digital measuring instrument USB interface and analog voltage output Well-arranged membrane keypad Two relays for programming setpoint values Can be used for controlling valves Display digital LED, height 10 mm Graphic display 60 x 18 mm Resolution 1 digit Read-out 10 per sec Thresholds 2 x 230 VAC1, 4 A Independent adjustable Switching accuracy/hysteresis +-1 Digit Power max. 20 W Vacuum connection depend on sensor Ambient conditions 0 - 40 °C and max. 90 % rh, 0 - 60 °C during storage
https://www.info-tek.com.tr/multi-range-vacuum-gauge-mrv-100LAUDA Contact Angle Surface Analyzer LSA100
Wetting of surfaces and solid-liquid-interaction can be precisely measured with contact angle instruments. The LAUDA Surface Analysers series LSA 60, 100 and 200 can be adapted to any laboratory requirement. Especially the easy handling and the very comprehensive software support the daily routine in the laboratory and allow precise measurement results. LAUDA Scientific offers you innovative features such as simultaneous measurements in projection and top-view, telecentric lenses for research applications or non-contact dosing systems.
https://www.info-tek.com.tr/lauda-contact-angle-surface-analyzer-lsa100Burning Behaviour of Bunched Cables - EN 50399
EN 50399, ısı bırakma ölçümü ve değiştirilmiş hava giriş sistemi ilavesiyle IEC 60332-3'e dayanıyordu. Bu, teçhizatın egzoz sistemine küçük bir aletli kanal bölümü yerleştirmek ve bunu FTT gaz analiz cihazı ve yazılımı ile birlikte kullanmak suretiyle gerçekleştirilir. Kanal bölümü tüm gaz örnekleme problarını, sıcaklık ve kütle akış problarını barındırır ve duman ölçüm sistemi için portlara sahiptir. Gaz analiz cihazı, aşağıdakileri içeren 19 inç bir alet rafına yerleştirilmiştir: FTT İkili Konik Kalorimetreye, ISO 9705 Oda / Köşe testine veya SBI'ye sahip olan müşteriler, IEC 60332-3'ten ısı yayılma hızını ölçmek için koni araçlarını kullanabilir. Alternatif olarak, EN 50399 Gaz Analizi rafı, diğer kalorimetreleri (örneğin FTT İkili Koni Kalorimetresi vb.) Enstrümanlandırmak için kullanılabilir. Birincil ısı tahliyesi ölçümü için sıcaklık ve basınç telafisi ile birlikte verilen Oksijen Analiz Cihazı (paramanyetik) Isı salımı ölçümünde kullanım için Karbon Dioksit Analizörü (kızılötesi) Analizden önce numune gazları iyileştirmek için çift kademeli kurum filtresi, soğutucu soğuk tuzak, kurutma kolonu, pompa ve atık regülatörleri Duman ölçüm sistemi kontrolleri (satın alındıysa). Veri kaydedici (satın alındıysa)
https://www.info-tek.com.tr/burning-behaviour-of-bunched-cables-en-50399Rotary Vane Vacuum Pump- R-4SN
Features *Compact structure*Very good sealing*No returning throughput*Oil-spout prevention*Low noise*Oil-observation window*Handle for easy transportation*High flow rate*Low and stable ultimate vacuum*High evaporation resistance*Comparatively high chemical resistance*High longevity*Low maintenance rate*Low oil mist*Gas ballast valve*Overcurrent protection*Fulfills IP54 standards Model R-4SN Number of Stages Single Flow Rate (L/min) 50 Ultimate Vacuum (mbar) 2.5 × 10-2 Power (W) 180 Motor rotation(RPM) 1400 Noise Level (dB) < 60 Oil Capacity (L) 0.25 IP Code IP40 Weight (kg) 13.5 Inlet and Outlet Specifications 5/8" SAE Male 7/16" SAE Male
https://www.info-tek.com.tr/rotary-vane-vacuum-pump-r-4snATR BR
SPECIFICATIONS ATR-BR Measuring scales Refractive Index (RI), Sucrose (%Brix), others on request Measuring range 1.32000 - 1.54000 RI / 100% Brix Resolution 0.00001 RI / 0.01% Brix Precision Measuring range 1.32 - 1.44: ± 0.00002 RI / ± 0.01% Brix *Measuring range 1.44 - 1.54: ± 0.00003 RI / ± 0.01% Brix * Reproducibility ± 0.00001 RI / ± 0.01% Brix Ambient temperature + 10° to + 40°C Automatic temperature compensation + 5° to + 50°C Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Technical control sample No control Measurement mode Single measurement Prism Sapphire Light source / wavelength LED, interference filter 589 nm Display Back-lit LCD, 16 x 16 characters Operation 20 key membrane including function keys Interfaces 1 x RS232 C serial and parallel Standard model ATR-BR Conformity International Pharmacopoea, ASTM, AOAC, DIN, FDA, ICUMSA and others Highlights Stand alone device; high quality and precision; very stable measurements: user friendly operation;excellent price performance ratio, very flat and small sample room for easy cleaning
https://www.info-tek.com.tr/atr-brChest Freezer Order No 6345
Applications Only a reliable cooling technology and a first-class insulation ensure trouble-free long-term storage of cell lines, human, animal and plant tissues, fractions of the blood, vaccines, or reference cultures of micro-organisms, such as bacteria, yeasts, viruses and fungi.
https://www.info-tek.com.tr/chest-freezer-order-no-6345Upright Freezer Order No 6485
Only a reliable cooling technology and a first-class insulation ensure trouble-free long-term storage of cell lines, human, animal and plant tissues, fractions of the blood, vaccines, or reference cultures of micro-organisms, such as bacteria, yeasts, viruses and fungi.
https://www.info-tek.com.tr/upright-freezer-order-no-6485Incubation/Inactivation Bath Order No 1108
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1108Orbital-Rocking Shaker Order No 3011
Applications In AIDS research, for diagnostic tests with test plates, or for growing cell cultures and micro-organisms this unit has become indispensable. The unit is well-suited for use in laboratories, incubation and moderating rooms in ambient temperatures between +10 and +50 °C.
https://www.info-tek.com.tr/orbital-rocking-shaker-order-no-3011Pellet Press Dies | FTIR + XRF Dies
Ideal for producing high-quality pellets Evacuable for sample pellet clarity and quality Hardened Stainless Steel for durability Highly Polished Pellets Wide range of sizes and load capabilities Buy FTIR or XRF die
https://www.info-tek.com.tr/pellet-press-dies-ftir-xrf-diesMMM Ecocell 707 - ECO line
Convincingly cost saving laboratory dryer 707-liter chamber volume Working temperature of from +5°C over ambient temperature up to 250/300°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-ecocell-707-eco-lineMMM INCUCELL 707 - ECO line
Suitable for safe treatment of microbiological cultures. The INCUCELL line produces no noise and provides a very soft air flow within the chamber. These devices can be used especially in biological and microbiological laboratories, quality tests in pharmaceutical and cosmetic industry, and for testing in veterinary medicine and food industry. Internal volume: 22, 55, 111, 222, 404, and 707 liters Working temperature range: from 5°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 707-liter chamber volume Working temperature of from +5°C above ambient up to 100°C Noiseless operation and fine air flow in the chamber High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry; suitable for safe processing of microbiological cultures Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume707 l depth520 mm width940 mm height1410 mm Tray standard equipment2 pcs storage area (w × d)920×485 mm racks19 max. number distance between guide rails70 mm Maximal weight of the load*) inside the oven130 kg/oven per tray50 kg/tray Door 2 pcs External dimensions (including door and handle) depth790 mm diameter of the air branch outer / inner52/49 mm width1160 mm height, incl. Feet (N) and Rolls (K)1910 (K) Package dimensions (three layers carton) depth860 mm width1230 mm depth2085 mm Weight brut240 kg nett215 kg Working temperature (beginning of the regulation) from 5 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)< 1,5 °C Time required to reach 37 °C with closed air flap and voltage 230 V 59 min Heat emission at 37 °C 85 W Air exchange speed at 37 °C 5 per hour Electricity - mains 50/60 Hz max. power0,9 kW nominal voltage230 V current3,9 A power by stand by5 W *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).
https://www.info-tek.com.tr/mmm-incucell-707-eco-lineRing/Plate Tensiometer TD 3
Technical features TD 3 Measuring range surface and interfacial tension mN/m 0…300 (ring method); 0…999 (plate method); resolution: 0.01 Density measurement kg/m3 0…2000; resolution: 1 Weight measurement mg 0…5000; resolution: 0.1 Measuring mode selection/parameter input Ring/plate/density/weight/menu-driven Measuring point interval Minute 0...120, selectable Measurement memory Results max. 500, with date and time Ring correction Automatic based on Zuidema and Waters Stability criterion Standard deviation over option of 3…9 measurements Temperature range (PTT) °C 5…80 (±0.1) Magnetic stirrer Integrated into the PTT, adjustable (10 levels) Stage movement mm/s 0.1…1 (10 levels) Interface RS 232, Command remote control Control and evaluation Command remote control (control, display, documented data storage) Ambient temperature range °C 10…40 Power consumption W 10 Dimensions (WxDxH) mm 245x205x335 Weight kg 9.5 Cat. No. 90…240 V; 50/60 Hz LMT 850 incl. power supply unit
https://www.info-tek.com.tr/ringplate-tensiometer-td-3Centrifuge Z 167 M
he powerful and compact model Z 167 M is a replacement for our previous model Z 160 M. A brushless, maintenance free motor provides extremely fast acceleration and deceleration of the 18 place rotor. This Micro Centrifuge is supplied with the 18 place rotor for 1.5/2.0 ml tubes.
https://www.info-tek.com.tr/centrifuge-z-167-mOSU Rate of Heat Release Apparatus- ASTM E906 Standard
Paslanmaz çelik yalıtımlı test odası, contalı kapı ve görüş penceresi Isı kaynağı olarak eşleşen set kızdırma çubuğu elemanları (korozyona dayanıklı paslanmaz çelik gövdeli) Isı akısı homojenlik ayarının kolaylığı için ikili globar güç kontrolörleri Üst pilot, kıvılcım ateşlemeli alt kalibrasyon ve metan gazı brülörleri ile kalibrasyon Bacada beş sıcak termokupl bağlantı ve hava odasındaki beş soğuk termokupl bağlantı ile ısı ölçümü için termopil Hava dağıtım sistemi ve egzoz yığını Numune tutucu, baskı plakası, montaj braketi ve damlama kabı ile Tekli kontrol ünitesi 19 inç rafa yerleştirilmiştir, şunlarla: - Radyant ısı kaynağı için tristör kontrolü - Brülörler için akış kontrolü - Hava besleme sistemi kontrolleri Kalibrasyon ısı akısı ölçer Yazılım, arayüz, bilgisayar ve lazer yazıcı
https://www.info-tek.com.tr/osu-rate-of-heat-release-apparatus-astm-e906-standardDigital Hot Plates-WH200D-1K
PID temperature control technology for accurate and reliable results Suitable for complicated temperature control requirements Bright LED screen can display both set value and actual temperature Convenient temperature setting via on-touch control Timer function for automatic heating up to 100 hours Alarm signal output which can be applied to stop the operation of the hot plate and the other connected devices External Pt100 temperature sensor connection for direct and precise control of the actual temperature
https://www.info-tek.com.tr/digital-hot-plates-wh200d-1kZ 446 K
Bakım gerektirmeyen indüksiyon motor LCD ekranlı mikroişlemci kontrolcü Emniyet kapak kilidi (Motorlu) Rotorun takılmasıyla aşırı hıza karşı otomatik rotor tanıma sistemi Rotor ve aksesuarlarında büyük çeşitlilik Aktif degesizlik algılama ve kesme Kolaylıkla rotor değişimi yapılmaktadır Melodi seçenekleriyle proses sonunda sesli sinyal verme özelliği CFC - kendinden soğutma sistemi (Z 446 K) Ön soğutma programı (Z 446 K) Gürültü seviyesi < 65 dBA (rotora bağlıdır) Geliştirilmiş havalandırma sistemiyle örnekleri serin tutar
https://www.info-tek.com.tr/z-446-kChest Freezer Order No 6380
Applications Only a reliable cooling technology and a first-class insulation ensure trouble-free long-term storage of cell lines, human, animal and plant tissues, fractions of the blood, vaccines, or reference cultures of micro-organisms, such as bacteria, yeasts, viruses and fungi.
https://www.info-tek.com.tr/chest-freezer-order-no-6380Incubation/Inactivation Bath Order No 1112
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1112Orbital-Rocking Shaker Order No 3012
Applications In AIDS research, for diagnostic tests with test plates, or for growing cell cultures and micro-organisms this unit has become indispensable. The unit is well-suited for use in laboratories, incubation and moderating rooms in ambient temperatures between +10 and +50 °C.
https://www.info-tek.com.tr/orbital-rocking-shaker-order-no-3012Spares + consumables for pellet dies | FTIR, KBr + XRF
Die Bases Die Extractor Rings Retainer Rings O-Rings Pellet Holders Die Spares
https://www.info-tek.com.tr/spares-consumables-for-pellet-dies-ftir-kbr-xrfMMM Durocell 22 - ECO line
Highly durable laboratory oven 22-liter chamber volume Working temperature of from +5°C over ambient temperature up to 125°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of laboratory materials in laboratories and industry; perfect anticorrosive protection of all chamber parts (protective Epolon plastic) enabling wirk with acids and dases, acid and alkaline hydrolysis etc. High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-durocell-22-eco-lineMMM INCUCELL V 22 - ECO line
Suitable for safe processing of microbiological cultures. The INCUCELL V line (with a fan) ensures quicker and more precise temperature distribution with small deviations. These units are to be used especially in biological and microbiological laboratories. They can also be used for quality tests in the pharmaceutical industry and cosmetics, for testing in the veterinary medicine, and in the food industry. Inner volume of the chamber: 22, 55, 111, 222, 404, and 707 liters Working temperature: From 10°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel, DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 22-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume22 l depth320 mm width240 mm height300 mm Tray standard equipment2 pcs storage area (w × d)185×265 mm racks4 max. number distance between guide rails60 mm Maximal weight of the load *) inside the oven25 kg/oven per tray10 kg/tray Door 1 pcs External dimensions (including door and handle) depth560 mm diameter of the air branch outer/inner52/49 mm width406 mm height, incl. Feet (N) and Rolls (K)610 (N) Package dimensions (three layers carton) depth720 mm width500 mm depth810 mm Weight brut36 kg nett31 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)0,1 °C space deviation cca (±)0,4 °C Time required to reach 37 °C with closed air flap and voltage 230 V 8 min Heat emission at 37 °C 70 W Air exchange speed at 37 °C 45 per hour Electricity - mains 50/60 Hz max. power0,96 kW nominal voltage230 V current4,2 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-v-22Fire Propagation Apparatus -FM 4910; ASTM E2058; ISO 12136
Global tarafından temiz oda ve kablo uygulamaları dahil olmak üzere çeşitli sigorta endüstrisi normları için yaygın olarak kullanılan bir araçtır. Metot ASTM tarafından ASTM E2058 olarak ISO ve ISO 12136 olarak standardize edilmiştir. FTT FPA şunları belirlemek için kullanılabilir: Kritik ısı akışı Termal Tepki Parametresi (TRP) Etkili yanma ısısı Kimyasal ve konvektif ısı yayılma oranları Yangın Yayılma İndeksi (FPI) Ayrıca aşağıdakileri ölçmek için de kullanılabilir: Ortalama Korozyon İndeksi Duman verimi
https://www.info-tek.com.tr/fire-propagation-apparatus-fm-4910-astm-e2058-iso-12136Soxhlet 6-Plate Heater- WH-106
The distance between each hole is 55mm which is according to DIN 44548 and wide enough for users to handle the samples in back row conveniently. WH-106 contains six embedded heating plates with 85mm diameter, and its heating components are made in Germany, rugged and easy to maintain. Each plate with a heating indicato is controlled independently, and the temperature can reach 425℃ . For safety reason, each plate is surrounded by a rim for keeping electronics from spilling. The whole housing is made of stainless steel with paint coating.
https://www.info-tek.com.tr/soxhlet-6-plate-heater-wh-106LS-X (Lab-Shaker)
Kuhner LS-X, sürekli ve bakım gerektirmeyen çalışma için tasarlanmış sağlam bir tezgah çalkalayıcıdır.
https://www.info-tek.com.tr/ls-x-lab-shakerChest Freezer Order No 6381
Applications Only a reliable cooling technology and a first-class insulation ensure trouble-free long-term storage of cell lines, human, animal and plant tissues, fractions of the blood, vaccines, or reference cultures of micro-organisms, such as bacteria, yeasts, viruses and fungi.
https://www.info-tek.com.tr/chest-freezer-order-no-6381Incubation/Inactivation Bath Order No 1113
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1113Heated Platens | Electrically Powered
Controlled temperature to 300°C with water cooling 15 Ton load bearing capacity 100mm diameter pressing surface Compatible with all Specac Atlas Hydraulic Presses CE Safety approved
https://www.info-tek.com.tr/heated-platens-electrically-poweredMMM Durocell 55 - ECO line
Highly durable laboratory oven 55-liter chamber volume Working temperature of from +5°C over ambient temperature up to 125°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of laboratory materials in laboratories and industry; perfect anticorrosive protection of all chamber parts (protective Epolon plastic) enabling wirk with acids and dases, acid and alkaline hydrolysis etc. High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-durocell-55-eco-lineMMM INCUCELL V 55 - ECO line
Suitable for safe processing of microbiological cultures. The INCUCELL V line (with a fan) ensures quicker and more precise temperature distribution with small deviations. These units are to be used especially in biological and microbiological laboratories. They can also be used for quality tests in the pharmaceutical industry and cosmetics, for testing in the veterinary medicine, and in the food industry. Inner volume of the chamber: 22, 55, 111, 222, 404, and 707 liters Working temperature: From 10°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel, DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 55-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume55 l depth370 mm width400 mm height350 mm Tray standard equipment2 pcs storage area (w × d)380×335 mm racks4 max. number distance between guide rails70 mm Maximal weight of the load *) inside the oven50 kg/oven per tray20 kg/tray Door 1 pcs External dimensions (including door and handle) depth640 mm diameter of the air branch outer/inner52/49 mm width620 mm height, incl. Feet (N) and Rolls (K)680 (N) Package dimensions (three layers carton) depth730 mm width700 mm depth875 mm Weight brut66 kg nett55 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)<=0,3 °C Time required to reach 37 °C with closed air flap and voltage 230 V 41 min Heat emission at 37 °C 80 W Air exchange speed at 37 °C 45 per hour Electricity - mains 50/60 Hz max. power0,7 kW nominal voltage230 V current3 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-v-55-eco-lineES-X (Lab-Shaker)
Nemli inkübatörlerde kullanıma uygun ayrı kontrol üniteli çalkalayıcı, ES-X, ayrı bir kontrolöre sahip özel olarak tasarlanmış bir çalkalayıcıdır.
https://www.info-tek.com.tr/es-x-lab-shakerChest Freezer Order No 6382
Applications Only a reliable cooling technology and a first-class insulation ensure trouble-free long-term storage of cell lines, human, animal and plant tissues, fractions of the blood, vaccines, or reference cultures of micro-organisms, such as bacteria, yeasts, viruses and fungi.
https://www.info-tek.com.tr/chest-freezer-order-no-6382Incubation/Inactivation Bath Order No 1002
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1002Mini-Film Maker | Polymer Film Maker
Quick and reproducable thin film production Sample melt points from ambient to 250°C Standard film sizing rings of 50, 100, 250 & 500 microns Dedicated film maker accessory with hydraulic press and integrated heated platens
https://www.info-tek.com.tr/mini-film-maker-polymer-film-makerMMM Durocell 111 - ECO line
Highly durable laboratory oven 111-liter chamber volume Working temperature of from +5°C over ambient temperature up to 125°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of laboratory materials in laboratories and industry; perfect anticorrosive protection of all chamber parts (protective Epolon plastic) enabling wirk with acids and dases, acid and alkaline hydrolysis etc. High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-durocell-111-eco-lineMMM INCUCELL V 111 - ECO line
Suitable for safe processing of microbiological cultures. The INCUCELL V line (with a fan) ensures quicker and more precise temperature distribution with small deviations. These units are to be used especially in biological and microbiological laboratories. They can also be used for quality tests in the pharmaceutical industry and cosmetics, for testing in the veterinary medicine, and in the food industry. Inner volume of the chamber: 22, 55, 111, 222, 404, and 707 liters Working temperature: From 10°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel, DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 111-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume111 l depth370 mm width540 mm height530 mm Tray standard equipment2 pcs storage area (w × d)520×335 mm racks7 max. number distance between guide rails70 mm Maximal weight of the load *) inside the oven50 kg/oven per tray20 kg/tray Door 1 pcs External dimensions (including door and handle) depth640 mm diameter of the air branch outer/inner52/49 mm width760 mm height, incl. Feet (N) and Rolls (K)860 (N) Package dimensions (three layers carton) depth730 mm width830 mm depth1060 mm Weight brut87 kg nett75 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)<=0,3 °C Time required to reach 37 °C with closed air flap and voltage 230 V 51 min Heat emission at 37 °C 95 W Air exchange speed at 37 °C 49 per hour Electricity - mains 50/60 Hz max. power0,7 kW nominal voltage230 V current3 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-v-111-eco-line3 Metre Cube Smoke Density Apparatus IEC 61034; BS 6853; BS 6724; BS 7622
3 Metre Küp, tanımlanmış koşullar altında elektrik kabloları yakıldığında, örneğin yatay olarak yanan birkaç kabloda duman emisyonunu ölçmek için kullanılır. Ekipman bir kübik mahfaza ve fotometrik bir sistem içerir. Ünite şunları içerir: 3 Metre Küp montajı Fotometrik sistem, standlar, fanlar ve örnek montaj çerçeveleri Tahliye fanı ve kanal Grafik Kaydedici veya Windows Yazılımı
https://www.info-tek.com.tr/3-metre-cube-smoke-density-apparatus-iec-61034-bs-6853-bs-6724-bs-7622SBM/SS-X (Rack-Shaker)
Kuhner Raf Çalkalayıcı SBM / SS-X, çevre odaları, laboratuvarlar ve koridorlar için tasarlanmış, yerden tasarruf sağlayan bir çalkalayıcı sistemidir.
https://www.info-tek.com.tr/sbmss-x-rack-shakerChest Freezer Order No 6383
Applications Only a reliable cooling technology and a first-class insulation ensure trouble-free long-term storage of cell lines, human, animal and plant tissues, fractions of the blood, vaccines, or reference cultures of micro-organisms, such as bacteria, yeasts, viruses and fungi.
https://www.info-tek.com.tr/chest-freezer-order-no-6383Incubation/Inactivation Bath Order No 1003
Applications The Water Bath is successfully used for incubations and inactivations of cultures, as well as e. g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1003Pellet Press Spares | KBr Powder + More
KBr Powder Thin Film Card Holders Aluminium Foil Load Gauge Kit Hydraulic Oil Specacards
https://www.info-tek.com.tr/pellet-press-spares-kbr-powder-moreMMM Durocell 222 - ECO line
Highly durable laboratory oven 202-liter chamber volume Working temperature of from +5°C over ambient temperature up to 125°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of laboratory materials in laboratories and industry; perfect anticorrosive protection of all chamber parts (protective Epolon plastic) enabling wirk with acids and dases, acid and alkaline hydrolysis etc. High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-durocell-222-eco-lineMMM INCUCELL V 222 - ECO line
Suitable for safe processing of microbiological cultures. The INCUCELL V line (with a fan) ensures quicker and more precise temperature distribution with small deviations. These units are to be used especially in biological and microbiological laboratories. They can also be used for quality tests in the pharmaceutical industry and cosmetics, for testing in the veterinary medicine, and in the food industry. Inner volume of the chamber: 22, 55, 111, 222, 404, and 707 liters Working temperature: From 10°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel, DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 222-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume222 l depth520 mm width540 mm height760 mm Tray standard equipment2 pcs storage area (w × d)520×485 mm racks10 max. number distance between guide rails70 mm Maximal weight of the load *) inside the oven70 kg/oven per tray30 kg/tray Door 1 pcs External dimensions (including door and handle) depth790 mm diameter of the air branch outer/inner52/49 mm width760 mm height, incl. Feet (N) and Rolls (K)1095 (N) Package dimensions (three layers carton) depth860 mm width860 mm depth1260 mm Weight brut116 kg nett100 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)<=0,3 °C Time required to reach 37 °C with closed air flap and voltage 230 V 66 min Heat emission at 37 °C 95 W Air exchange speed at 37 °C 24 per hour Electricity - mains 50/60 Hz max. power0,7 kW nominal voltage230 V current3 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-v-222-eco-lineDensity of Smoke from the Burning or Decomposition of Plastics ASTM D2843
ASTM D2843 Duman Yoğunluğu Testinin, kontrollü yanma veya ayrışma koşulları altında plastiklerin duman üretme özelliklerini ölçmek için kullanılması amaçlanmıştır. Ölçümler, kontrollü, standartlaştırılmış koşullar altında üretilen toplanmış bir duman hacminden ışık iletiminin kaybı açısından yapılır. Cihaz, test sırasında alev ve dumanın gözlenebileceği şekilde imal edilmiştir. Bu test, belirtilen koşullar altında basit, doğrudan ve anlamlı bir şekilde üretilen duman gizliliği miktarının ölçülmesini sağlar. Yanıcı maddeler tarafından üretilen dumanın görme engelini belirleme derecesi, büyüklük ve malzeme, nem, cereyan, sıcaklık ve oksijen kaynağı şeklindeki değişikliklerden etkilenebilir. Bir malzeme üzerinde yapılan bu testler, plastiklerin göreceli duman engelleme özelliklerinin karşılaştırılmasında önemli bir değer olabilir.
https://www.info-tek.com.tr/density-of-smoke-from-the-burning-or-decomposition-of-plastics-astm-d2843Chest Freezer Order No 6384
Applications Only a reliable cooling technology and a first-class insulation ensure trouble-free long-term storage of cell lines, human, animal and plant tissues, fractions of the blood, vaccines, or reference cultures of micro-organisms, such as bacteria, yeasts, viruses and fungi.
https://www.info-tek.com.tr/chest-freezer-order-no-6384Incubation/Inactivation Water Bath Order No 1004
Applications The Water Bath is successfully used for incubations and inactivations of cultures, e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples, as well as for heating up medical compresses/hot packs.
https://www.info-tek.com.tr/incubationinactivation-water-bath-order-no-1004Constant Thickness Film Maker
Up to 300°C operation 15 minute cycle time typical 4 Ton load limit 0.015, 0.025, 0.05, 0.1, 0.25 and 0.50mm films of 29mm diameter Easy film release Operates with Heated Platens
https://www.info-tek.com.tr/constant-thickness-film-makerMMM VENTICELL 22 - ECO line
Accurate and quick laboratory oven 22-liter chamber volume Working temperature of from +10°C over ambient temperature up to 250/300 °C Patented system of forced air flow in the chamber ensures a homogenous temperature profile for all processes of drying, heating and sterilizing materials in laboratories High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Greater speed and accuracy of all tempering procedures ensures cost-saving operation; suitable especially for materials of high humidity, for demanding and accurate tests and processes Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-venticell-22-eco-lineMMM INCUCELL V 404 - ECO line
Suitable for safe processing of microbiological cultures. The INCUCELL V line (with a fan) ensures quicker and more precise temperature distribution with small deviations. These units are to be used especially in biological and microbiological laboratories. They can also be used for quality tests in the pharmaceutical industry and cosmetics, for testing in the veterinary medicine, and in the food industry. Natural, precise – laboratory incubator 404-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume404 l depth520 mm width540 mm height1410 mm Tray standard equipment2 pcs storage area (w × d)520×485 mm racks19 max. number distance between guide rails70 mm Maximal weight of the load *) inside the oven100 kg/oven per tray30 kg/tray Door 1 pcs External dimensions (including door and handle) depth790 mm diameter of the air branch outer/inner52/49 mm width760 mm height, incl. Feet (N) and Rolls (K)1910 (K) Package dimensions (three layers carton) depth860 mm width830 mm depth2085 mm Weight brut175 kg nett150 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)<=0,8 °C Time required to reach 37 °C with closed air flap and voltage 230 V 38 min Heat emission at 37 °C 115 W Air exchange speed at 37 °C 18 per hour Electricity - mains 50/60 Hz max. power1,3 kW nominal voltage230 V current5,6 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-404-eco-line-1