Arama Sonuçları..
Toplam 115 kayıt bulundu.
ISF1-X (Climo-Shaker)
Mikrobiyal, memeli ve bitki hücresi uygulamaları için istiflenebilir inkübatör çalkalayıcı
https://www.info-tek.com.tr/isf1-x-climo-shakerATR P
SPECIFICATIONS ATR-P Measuring scales Refractive Index (RI), Sucrose (%Brix)Up to 1000 scales freely definable Measuring range 1.32000 - 1.54000 RI / 100% Brix Resolution 0.00001 RI / 0.01% Brix Precision ± 0,00002 RI / ± 0.02% Brix Reproducibility ± 0.00001 RI / ± 0.01% Brix Ambient temperature + 10° to + 40°C Automatic temperature compensation + 5° to + 50°C Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Temperature controlTemperature range Temperature control prism / sample by external water bath5°C / 50°C Measurement mode Single sample or flow through measurement / horizontal or vertical usage Prism Sapphire Light source / wavelength LED, interference filter 589 nm Display 7" Touchscreen, 800 x 480 Pixel, 16 Bit colors Operation Touchscreen, keyboard**, mouse**, barcode reader**, remote via PC** Interfaces 1 x RS232 C serial, 3 x USB (A), 1 x USB (B), 1 x Ethernet, Easy connection of keyboard, mouse, printer, barcode reader,PC and network Conformity International Pharmacopoea, ASTM, AOAC, DIN, FDA, ICUMSA and others Highlights Robust stainless steel measuring head for rough enviroments; High performance and accuracy; Continuous measurement;ESH¹ chamber; MBS² as stand alone with L-Display or polarimeter; Easy calibration; GLP/GMP;With theL-Display: Maintenancefriendlybyremotediagnostic; Intuitive userhandling guided OPsystem; Installationwizard;Full traceability of records; Ext. LIMS integration; Huge storage for 1000 products each with 1000 methods; 21 CFR part 11ready conformity³1 Easy sample handling; ² Modular build-in-system; 3 Optional software module for the L-Display Weight / dimensions Measuring Head: 4.5 kg; 200 x 160 x 135 mm (width x depth x height)L-Display: 3.0 kg; 240 x 190 x 150 mm (width x depth x height)
https://www.info-tek.com.tr/atr-pIncubation/Inactivation Bath Order No 1105
Applications The Water Bath is successfully used for heating up medical compresses/hot packs as well as for incubations and inactivations of cultures, e. g. for warming bacteriological media, processing chemical reactions or thawing frozen samples
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1105Orbital Shaker Order No 3020
Applications This powerful orbital shaker is preferably used for e. g. analytical or diagnostic applications in the pharmaceutical industry, chemistry, biology, in plant breeding or nutritional industry. It is well-suited for use in laboratories, incubation and moderating rooms in ambient temperatures between +10 and +50 °C.
https://www.info-tek.com.tr/orbital-shaker-order-no-3020XRF Pellets – high throughput, high quality
32mm and 40mm pellet sizes Ejects pellet without awkward user handling Works seamlessly with Autotouch automatic press cycle Premium build material for durability Simple design for easy use
https://www.info-tek.com.tr/xrf-pellets-high-throughput-high-qualityMMM Ecocell 404 - ECO line
Convincingly cost saving laboratory dryer 404-liter chamber volume Working temperature of from +5°C over ambient temperature up to 250/300°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-ecocell-404-eco-lineMMM INCUCELL 404 - ECO line
Suitable for safe treatment of microbiological cultures. The INCUCELL line produces no noise and provides a very soft air flow within the chamber. These devices can be used especially in biological and microbiological laboratories, quality tests in pharmaceutical and cosmetic industry, and for testing in veterinary medicine and food industry. Internal volume: 22, 55, 111, 222, 404, and 707 liters Working temperature range: from 5°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 404-liter chamber volume Working temperature of from +5°C above ambient up to 100°C Noiseless operation and fine air flow in the chamber High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry; suitable for safe processing of microbiological cultures Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume404 l depth520 mm width540 mm height1410 mm Tray standard equipment2 pcs storage area (w × d)520×485 mm racks19 max. number distance between guide rails70 mm Maximal weight of the load*) inside the oven100 kg/oven per tray30 kg/tray Door 1 pcs External dimensions (including door and handle) depth790 mm diameter of the air branch outer / inner52/49 mm width760 mm height, incl. Feet (N) and Rolls (K)1910 (K) Package dimensions (three layers carton) depth860 mm width830 mm depth2085 mm Weight brut175 kg nett150 kg Working temperature (beginning of the regulation) from 5 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)< 1 °C Time required to reach 37 °C with closed air flap and voltage 230 V 41 min Heat emission at 37 °C 65 W Air exchange speed at 37 °C 5 per hour Electricity - mains 50/60 Hz max. power0,9 kW nominal voltage230 V current3,9 A power by stand by5 W *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).
https://www.info-tek.com.tr/mmm-incucell-404-eco-lineZ 207 M
The Microlitre Centrifuge, Z 207 M was designed specifically for small, compact spaces, suitable in any laboratory setting. The rapid acceleration allows short running time, with a max. speed of 13,500 rpm. Even with the high speed, this centrifuge is pleasantly quite. With this centrifuge, there is the option for a 24 x place mircolitre rotor, optional with hermetically sealed lid, and a rotor for Spin Column Kits. The highlight feature of the Z 207 M is, the "Touch Operation" function, of the control panel. Easy to operate, no need to remove gloves! A crucial detail is the Air Cooling System, which is designed to keep your samples cool, even at maximum speed.
https://www.info-tek.com.tr/z-207-mMulti-Range Vacuum Gauge MRV 100
Measuring instrument for use in the coarse, fine and high vacuum ranges Can only be used with sensor Digital measuring instrument USB interface and analog voltage output Well-arranged membrane keypad Two relays for programming setpoint values Can be used for controlling valves Display digital LED, height 10 mm Graphic display 60 x 18 mm Resolution 1 digit Read-out 10 per sec Thresholds 2 x 230 VAC1, 4 A Independent adjustable Switching accuracy/hysteresis +-1 Digit Power max. 20 W Vacuum connection depend on sensor Ambient conditions 0 - 40 °C and max. 90 % rh, 0 - 60 °C during storage
https://www.info-tek.com.tr/multi-range-vacuum-gauge-mrv-100Rotary Vane Vacuum Pump- R-4SN
Features *Compact structure*Very good sealing*No returning throughput*Oil-spout prevention*Low noise*Oil-observation window*Handle for easy transportation*High flow rate*Low and stable ultimate vacuum*High evaporation resistance*Comparatively high chemical resistance*High longevity*Low maintenance rate*Low oil mist*Gas ballast valve*Overcurrent protection*Fulfills IP54 standards Model R-4SN Number of Stages Single Flow Rate (L/min) 50 Ultimate Vacuum (mbar) 2.5 × 10-2 Power (W) 180 Motor rotation(RPM) 1400 Noise Level (dB) < 60 Oil Capacity (L) 0.25 IP Code IP40 Weight (kg) 13.5 Inlet and Outlet Specifications 5/8" SAE Male 7/16" SAE Male
https://www.info-tek.com.tr/rotary-vane-vacuum-pump-r-4snISF4-X (Climo-Shaker)
Kuhner ISF4-X inkübatör çalkalayıcı, mevcut sıcaklık, nem ve CO2 kontrolü ile büyük çalkalama kapasitesi sunar.
https://www.info-tek.com.tr/isf4-x-climo-shakerATR BR
SPECIFICATIONS ATR-BR Measuring scales Refractive Index (RI), Sucrose (%Brix), others on request Measuring range 1.32000 - 1.54000 RI / 100% Brix Resolution 0.00001 RI / 0.01% Brix Precision Measuring range 1.32 - 1.44: ± 0.00002 RI / ± 0.01% Brix *Measuring range 1.44 - 1.54: ± 0.00003 RI / ± 0.01% Brix * Reproducibility ± 0.00001 RI / ± 0.01% Brix Ambient temperature + 10° to + 40°C Automatic temperature compensation + 5° to + 50°C Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Technical control sample No control Measurement mode Single measurement Prism Sapphire Light source / wavelength LED, interference filter 589 nm Display Back-lit LCD, 16 x 16 characters Operation 20 key membrane including function keys Interfaces 1 x RS232 C serial and parallel Standard model ATR-BR Conformity International Pharmacopoea, ASTM, AOAC, DIN, FDA, ICUMSA and others Highlights Stand alone device; high quality and precision; very stable measurements: user friendly operation;excellent price performance ratio, very flat and small sample room for easy cleaning
https://www.info-tek.com.tr/atr-brIncubation/Inactivation Bath Order No 1108
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1108Orbital-Rocking Shaker Order No 3011
Applications In AIDS research, for diagnostic tests with test plates, or for growing cell cultures and micro-organisms this unit has become indispensable. The unit is well-suited for use in laboratories, incubation and moderating rooms in ambient temperatures between +10 and +50 °C.
https://www.info-tek.com.tr/orbital-rocking-shaker-order-no-3011Pellet Press Dies | FTIR + XRF Dies
Ideal for producing high-quality pellets Evacuable for sample pellet clarity and quality Hardened Stainless Steel for durability Highly Polished Pellets Wide range of sizes and load capabilities Buy FTIR or XRF die
https://www.info-tek.com.tr/pellet-press-dies-ftir-xrf-diesMMM Ecocell 707 - ECO line
Convincingly cost saving laboratory dryer 707-liter chamber volume Working temperature of from +5°C over ambient temperature up to 250/300°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-ecocell-707-eco-lineMMM INCUCELL 707 - ECO line
Suitable for safe treatment of microbiological cultures. The INCUCELL line produces no noise and provides a very soft air flow within the chamber. These devices can be used especially in biological and microbiological laboratories, quality tests in pharmaceutical and cosmetic industry, and for testing in veterinary medicine and food industry. Internal volume: 22, 55, 111, 222, 404, and 707 liters Working temperature range: from 5°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 707-liter chamber volume Working temperature of from +5°C above ambient up to 100°C Noiseless operation and fine air flow in the chamber High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry; suitable for safe processing of microbiological cultures Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume707 l depth520 mm width940 mm height1410 mm Tray standard equipment2 pcs storage area (w × d)920×485 mm racks19 max. number distance between guide rails70 mm Maximal weight of the load*) inside the oven130 kg/oven per tray50 kg/tray Door 2 pcs External dimensions (including door and handle) depth790 mm diameter of the air branch outer / inner52/49 mm width1160 mm height, incl. Feet (N) and Rolls (K)1910 (K) Package dimensions (three layers carton) depth860 mm width1230 mm depth2085 mm Weight brut240 kg nett215 kg Working temperature (beginning of the regulation) from 5 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)< 1,5 °C Time required to reach 37 °C with closed air flap and voltage 230 V 59 min Heat emission at 37 °C 85 W Air exchange speed at 37 °C 5 per hour Electricity - mains 50/60 Hz max. power0,9 kW nominal voltage230 V current3,9 A power by stand by5 W *) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).
https://www.info-tek.com.tr/mmm-incucell-707-eco-lineLT-X (Lab-Therm)
İnkübatör çalkalayıcı, biyoteknoloji ve ilaç endüstrilerinin sallama ihtiyaçlarını karşılamak için özel olarak geliştirilmiştir.
https://www.info-tek.com.tr/lt-x-lab-thermIncubation/Inactivation Bath Order No 1112
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1112Orbital-Rocking Shaker Order No 3012
Applications In AIDS research, for diagnostic tests with test plates, or for growing cell cultures and micro-organisms this unit has become indispensable. The unit is well-suited for use in laboratories, incubation and moderating rooms in ambient temperatures between +10 and +50 °C.
https://www.info-tek.com.tr/orbital-rocking-shaker-order-no-3012Spares + consumables for pellet dies | FTIR, KBr + XRF
Die Bases Die Extractor Rings Retainer Rings O-Rings Pellet Holders Die Spares
https://www.info-tek.com.tr/spares-consumables-for-pellet-dies-ftir-kbr-xrfMMM Durocell 22 - ECO line
Highly durable laboratory oven 22-liter chamber volume Working temperature of from +5°C over ambient temperature up to 125°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of laboratory materials in laboratories and industry; perfect anticorrosive protection of all chamber parts (protective Epolon plastic) enabling wirk with acids and dases, acid and alkaline hydrolysis etc. High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-durocell-22-eco-lineMMM INCUCELL V 22 - ECO line
Suitable for safe processing of microbiological cultures. The INCUCELL V line (with a fan) ensures quicker and more precise temperature distribution with small deviations. These units are to be used especially in biological and microbiological laboratories. They can also be used for quality tests in the pharmaceutical industry and cosmetics, for testing in the veterinary medicine, and in the food industry. Inner volume of the chamber: 22, 55, 111, 222, 404, and 707 liters Working temperature: From 10°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel, DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 22-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume22 l depth320 mm width240 mm height300 mm Tray standard equipment2 pcs storage area (w × d)185×265 mm racks4 max. number distance between guide rails60 mm Maximal weight of the load *) inside the oven25 kg/oven per tray10 kg/tray Door 1 pcs External dimensions (including door and handle) depth560 mm diameter of the air branch outer/inner52/49 mm width406 mm height, incl. Feet (N) and Rolls (K)610 (N) Package dimensions (three layers carton) depth720 mm width500 mm depth810 mm Weight brut36 kg nett31 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)0,1 °C space deviation cca (±)0,4 °C Time required to reach 37 °C with closed air flap and voltage 230 V 8 min Heat emission at 37 °C 70 W Air exchange speed at 37 °C 45 per hour Electricity - mains 50/60 Hz max. power0,96 kW nominal voltage230 V current4,2 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-v-22LS-X (Lab-Shaker)
Kuhner LS-X, sürekli ve bakım gerektirmeyen çalışma için tasarlanmış sağlam bir tezgah çalkalayıcıdır.
https://www.info-tek.com.tr/ls-x-lab-shakerIncubation/Inactivation Bath Order No 1113
Applications The Water Bath is successfully used for incubations and inactivations of cultures, such as e.g. for warming bacteriological media, processing chemical reactions or thawing frozen samples.
https://www.info-tek.com.tr/incubationinactivation-bath-order-no-1113MMM Durocell 55 - ECO line
Highly durable laboratory oven 55-liter chamber volume Working temperature of from +5°C over ambient temperature up to 125°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of laboratory materials in laboratories and industry; perfect anticorrosive protection of all chamber parts (protective Epolon plastic) enabling wirk with acids and dases, acid and alkaline hydrolysis etc. High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-durocell-55-eco-lineMMM INCUCELL V 55 - ECO line
Suitable for safe processing of microbiological cultures. The INCUCELL V line (with a fan) ensures quicker and more precise temperature distribution with small deviations. These units are to be used especially in biological and microbiological laboratories. They can also be used for quality tests in the pharmaceutical industry and cosmetics, for testing in the veterinary medicine, and in the food industry. Inner volume of the chamber: 22, 55, 111, 222, 404, and 707 liters Working temperature: From 10°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel, DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 55-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume55 l depth370 mm width400 mm height350 mm Tray standard equipment2 pcs storage area (w × d)380×335 mm racks4 max. number distance between guide rails70 mm Maximal weight of the load *) inside the oven50 kg/oven per tray20 kg/tray Door 1 pcs External dimensions (including door and handle) depth640 mm diameter of the air branch outer/inner52/49 mm width620 mm height, incl. Feet (N) and Rolls (K)680 (N) Package dimensions (three layers carton) depth730 mm width700 mm depth875 mm Weight brut66 kg nett55 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)<=0,3 °C Time required to reach 37 °C with closed air flap and voltage 230 V 41 min Heat emission at 37 °C 80 W Air exchange speed at 37 °C 45 per hour Electricity - mains 50/60 Hz max. power0,7 kW nominal voltage230 V current3 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-v-55-eco-lineES-X (Lab-Shaker)
Nemli inkübatörlerde kullanıma uygun ayrı kontrol üniteli çalkalayıcı, ES-X, ayrı bir kontrolöre sahip özel olarak tasarlanmış bir çalkalayıcıdır.
https://www.info-tek.com.tr/es-x-lab-shakerMini-Film Maker | Polymer Film Maker
Quick and reproducable thin film production Sample melt points from ambient to 250°C Standard film sizing rings of 50, 100, 250 & 500 microns Dedicated film maker accessory with hydraulic press and integrated heated platens
https://www.info-tek.com.tr/mini-film-maker-polymer-film-makerMMM Durocell 111 - ECO line
Highly durable laboratory oven 111-liter chamber volume Working temperature of from +5°C over ambient temperature up to 125°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of laboratory materials in laboratories and industry; perfect anticorrosive protection of all chamber parts (protective Epolon plastic) enabling wirk with acids and dases, acid and alkaline hydrolysis etc. High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-durocell-111-eco-lineMMM INCUCELL V 111 - ECO line
Suitable for safe processing of microbiological cultures. The INCUCELL V line (with a fan) ensures quicker and more precise temperature distribution with small deviations. These units are to be used especially in biological and microbiological laboratories. They can also be used for quality tests in the pharmaceutical industry and cosmetics, for testing in the veterinary medicine, and in the food industry. Inner volume of the chamber: 22, 55, 111, 222, 404, and 707 liters Working temperature: From 10°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel, DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 111-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume111 l depth370 mm width540 mm height530 mm Tray standard equipment2 pcs storage area (w × d)520×335 mm racks7 max. number distance between guide rails70 mm Maximal weight of the load *) inside the oven50 kg/oven per tray20 kg/tray Door 1 pcs External dimensions (including door and handle) depth640 mm diameter of the air branch outer/inner52/49 mm width760 mm height, incl. Feet (N) and Rolls (K)860 (N) Package dimensions (three layers carton) depth730 mm width830 mm depth1060 mm Weight brut87 kg nett75 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)<=0,3 °C Time required to reach 37 °C with closed air flap and voltage 230 V 51 min Heat emission at 37 °C 95 W Air exchange speed at 37 °C 49 per hour Electricity - mains 50/60 Hz max. power0,7 kW nominal voltage230 V current3 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-v-111-eco-lineSBM/SS-X (Rack-Shaker)
Kuhner Raf Çalkalayıcı SBM / SS-X, çevre odaları, laboratuvarlar ve koridorlar için tasarlanmış, yerden tasarruf sağlayan bir çalkalayıcı sistemidir.
https://www.info-tek.com.tr/sbmss-x-rack-shakerPellet Press Spares | KBr Powder + More
KBr Powder Thin Film Card Holders Aluminium Foil Load Gauge Kit Hydraulic Oil Specacards
https://www.info-tek.com.tr/pellet-press-spares-kbr-powder-moreMMM Durocell 222 - ECO line
Highly durable laboratory oven 202-liter chamber volume Working temperature of from +5°C over ambient temperature up to 125°C Natural fine air flow in the chamber, noiseless operation High-quality and safe drying, heating and tempering of laboratory materials in laboratories and industry; perfect anticorrosive protection of all chamber parts (protective Epolon plastic) enabling wirk with acids and dases, acid and alkaline hydrolysis etc. High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-durocell-222-eco-lineMMM INCUCELL V 222 - ECO line
Suitable for safe processing of microbiological cultures. The INCUCELL V line (with a fan) ensures quicker and more precise temperature distribution with small deviations. These units are to be used especially in biological and microbiological laboratories. They can also be used for quality tests in the pharmaceutical industry and cosmetics, for testing in the veterinary medicine, and in the food industry. Inner volume of the chamber: 22, 55, 111, 222, 404, and 707 liters Working temperature: From 10°C above ambient temperature up to 100°C Inner glass door Inner chamber: Stainless steel, DIN 1.4301 (AISI 304) Natural, precise – laboratory incubator 222-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume222 l depth520 mm width540 mm height760 mm Tray standard equipment2 pcs storage area (w × d)520×485 mm racks10 max. number distance between guide rails70 mm Maximal weight of the load *) inside the oven70 kg/oven per tray30 kg/tray Door 1 pcs External dimensions (including door and handle) depth790 mm diameter of the air branch outer/inner52/49 mm width760 mm height, incl. Feet (N) and Rolls (K)1095 (N) Package dimensions (three layers carton) depth860 mm width860 mm depth1260 mm Weight brut116 kg nett100 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)<=0,3 °C Time required to reach 37 °C with closed air flap and voltage 230 V 66 min Heat emission at 37 °C 95 W Air exchange speed at 37 °C 24 per hour Electricity - mains 50/60 Hz max. power0,7 kW nominal voltage230 V current3 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-v-222-eco-lineRC2-X (Pilot-Shaker)
Kuhner, RC2-X'i özellikle büyük kapasiteli sarsıntı için geliştirdi. Erlenmeyer şişesi kelepçeleri, tüp tutucular veya yapışkan paspaslar vb. Takılabilen iki büyük C-boy tepsiyi (800 x 660 mm) kabul edecektir.
https://www.info-tek.com.tr/rc2-x-pilot-shakerMMM VENTICELL 22 - ECO line
Accurate and quick laboratory oven 22-liter chamber volume Working temperature of from +10°C over ambient temperature up to 250/300 °C Patented system of forced air flow in the chamber ensures a homogenous temperature profile for all processes of drying, heating and sterilizing materials in laboratories High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Greater speed and accuracy of all tempering procedures ensures cost-saving operation; suitable especially for materials of high humidity, for demanding and accurate tests and processes Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-venticell-22-eco-lineMMM INCUCELL V 404 - ECO line
Suitable for safe processing of microbiological cultures. The INCUCELL V line (with a fan) ensures quicker and more precise temperature distribution with small deviations. These units are to be used especially in biological and microbiological laboratories. They can also be used for quality tests in the pharmaceutical industry and cosmetics, for testing in the veterinary medicine, and in the food industry. Natural, precise – laboratory incubator 404-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume404 l depth520 mm width540 mm height1410 mm Tray standard equipment2 pcs storage area (w × d)520×485 mm racks19 max. number distance between guide rails70 mm Maximal weight of the load *) inside the oven100 kg/oven per tray30 kg/tray Door 1 pcs External dimensions (including door and handle) depth790 mm diameter of the air branch outer/inner52/49 mm width760 mm height, incl. Feet (N) and Rolls (K)1910 (K) Package dimensions (three layers carton) depth860 mm width830 mm depth2085 mm Weight brut175 kg nett150 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)<=0,8 °C Time required to reach 37 °C with closed air flap and voltage 230 V 38 min Heat emission at 37 °C 115 W Air exchange speed at 37 °C 18 per hour Electricity - mains 50/60 Hz max. power1,3 kW nominal voltage230 V current5,6 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-404-eco-line-1SR200-X (Pilot-Shaker)
Gereksinimlerinize göre uyarlanabilen ağır yükler için esnek çalkalama makinesi
https://www.info-tek.com.tr/sr200-x-pilot-shakerMMM VENTICELL 55 - ECO line
Accurate and quick laboratory oven 55-liter chamber volume Working temperature of from +10°C over ambient temperature up to 250/300 °C Patented system of forced air flow in the chamber ensures a homogenous temperature profile for all processes of drying, heating and sterilizing materials in laboratories High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Greater speed and accuracy of all tempering procedures ensures cost-saving operation; suitable especially for materials of high humidity, for demanding and accurate tests and processes Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-venticell-55-eco-lineMMM INCUCELL V 707 - ECO line
Natural, precise – laboratory incubator 707-liter chamber volume Working temperature of from +10°C above ambient up to 100°C Patented system of air flow in the chamber ensures quicker and more accurate distribution of the preset temperature in the chamber, which enables ideal heating of the samples High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door Model with a fan ensures quicker and more accurate distribution of temperature with small deviations; suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume707 l depth520 mm width940 mm height1410 mm Tray standard equipment2 pcs storage area (w × d)920×485 mm racks19 max. number distance between guide rails70 mm Maximal weight of the load *) inside the oven130 kg/oven per tray50 kg/tray Door 2 pcs External dimensions (including door and handle) depth790 mm diameter of the air branch outer/inner52/49 mm width1160 mm height, incl. Feet (N) and Rolls (K)1910 (K) Package dimensions (three layers carton) depth860 mm width1230 mm depth2085 mm Weight brut240 kg nett215 kg Working temperature (beginning of the regulation) from 10 °C above ambient temp. to:100 °C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca (±)<=0,2 °C space deviation cca (±)<=1,5 °C Time required to reach 37 °C with closed air flap and voltage 230 V 51 min Heat emission at 37 °C 135 W Air exchange speed at 37 °C 12 per hour Electricity - mains 50/60 Hz max. power1,3 kW nominal voltage230 V current5,6 A power by stand by5 W Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-incucell-v-707-eco-lineSR400-X (Pilot-Shaker)
Gereksinimlerinize göre uyarlanabilen ağır yükler için esnek çalkalama makinesi
https://www.info-tek.com.tr/sr400-x-pilot-shakerMMM VENTICELL 111 - ECO line
Accurate and quick laboratory oven 111-liter chamber volume Working temperature of from +10°C over ambient temperature up to 250/300 °C Patented system of forced air flow in the chamber ensures a homogenous temperature profile for all processes of drying, heating and sterilizing materials in laboratories High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Greater speed and accuracy of all tempering procedures ensures cost-saving operation; suitable especially for materials of high humidity, for demanding and accurate tests and processes Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-venticell-111-eco-lineMMM Friocell 55 - ECO line
The high technical standard of our FRIOCELL incubators allows tempering of samples, precise both in time and space. The unique cooling system offers an exact and cost saving simulation of the selected natural processes and reduces the samples evaporation. The incubators can be used in biotechnology, botany, zoology, food industry, cosmetics, chemical industry, etc. where it allows an extremely low duration of the temperature recovery. Inner volume: 55, 111, 222, 404, 707 and 1212 liters Working temperature: From 0.0°C up to 100°C Refrigerant: R 134a (R449a) Manual defrosting control Inner glass door Inner chamber: Stainless steel DIN 1.4301 (AISI 304) Precise, nature-adaptable, cost-saving – laboratory incubator 55-liter chamber volume Working temperature of from 0.0°C up to 100 °C Patented cooling system (ecological cooling medium R134a) offers a precise and quick simulation of natural processes and reduces the risk of samples evaporation; various types of the inner chamber lighting can be added to the unit High operation comfort; precise temperature regulation; possibility to reach even extremely short times of temperature changes and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door and possibility to regulate the fan speed Suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LCD display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Inner dimensions - Chamber, stainless steel volume55 l depth370 mm width400 mm height350 mm Volume of the steam space 89 cca l Trays, stainless steel *) Min. distance between trays70 mm number4/2 max./usual Storage area (w × d)380 × 335 mm Number of outer metal doors number1 pcs Number of inner glass doors number1 pcs Admissible weight of trays together inside the oven50 kg per 1 tray20 kg Electricity data Max. power700 W Protective systemIP 20 mains 50/60Hz230 V Temperature data Cooling/down time from 22 °C to 10 °C< 21 min Heating/up time to 37 °C from the ambient temperature11 min Working temperature from 0,0 to100 °C Temperature accuracy - in time0,2 ± °C Temperature accuracy - in space at 10 °C0,5 ± °C Recovery time after 30 s door open at 37 °C5 min at 50 °C6 min Heat emission at 37 °C55 W Outer dimensions, incl. door and handle, Feet (N) or Rollers (K) depth650 mm width620 mm height875 (N) mm Weight brut102 kg nett83 kg Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-friocell-55-eco-lineMMM VENTICELL 222 - ECO line
Accurate and quick laboratory oven 222-liter chamber volume Working temperature of from +10°C over ambient temperature up to 250/300 °C Patented system of forced air flow in the chamber ensures a homogenous temperature profile for all processes of drying, heating and sterilizing materials in laboratories High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Greater speed and accuracy of all tempering procedures ensures cost-saving operation; suitable especially for materials of high humidity, for demanding and accurate tests and processes Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-venticell-222-eco-lineMMM Friocell 111 - ECO line
Precise, nature-adaptable, cost-saving – laboratory incubator 111-liter chamber volume Working temperature of from 0.0°C up to 100 °C Patented cooling system (ecological cooling medium R134a) offers a precise and quick simulation of natural processes and reduces the risk of samples evaporation; various types of the inner chamber lighting can be added to the unit High operation comfort; precise temperature regulation; possibility to reach even extremely short times of temperature changes and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door and possibility to regulate the fan speed Suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LCD display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Inner dimensions - Chamber, stainless steel volume111 l depth370 mm width540 mm height530 mm Volume of the steam space 163 cca l Trays, stainless steel *) Min. distance between trays70 mm number7/2 max./usual Storage area (w × d)520 × 335 mm Number of outer metal doors number1 pcs Number of inner glass doors number1 pcs Admissible weight of trays together inside the oven50 kg per 1 tray20 kg Electricity data Max. power700 W Protective systemIP 20 mains 50/60Hz230 V Temperature data Cooling/down time from 22 °C to 10 °C< 21 min Heating/up time to 37 °C from the ambient temperature11 min Working temperature from 0,0 to100 °C Temperature accuracy - in time0,2 ± °C Temperature accuracy - in space at 10 °C0,5 ± °C Recovery time after 30 s door open at 37 °C5 min at 50 °C6 min Heat emission at 37 °C70 W Outer dimensions, incl. door and handle, Feet (N) or Rollers (K) depth750 mm width760 mm height1045 (N) mm Weight brut136 kg nett106 kg Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/friocell-111-eco-lineMMM VENTICELL 404 - ECO line
Accurate and quick laboratory oven 404-liter chamber volume Working temperature of from +10°C over ambient temperature up to 250/300 °C Patented system of forced air flow in the chamber ensures a homogenous temperature profile for all processes of drying, heating and sterilizing materials in laboratories High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Greater speed and accuracy of all tempering procedures ensures cost-saving operation; suitable especially for materials of high humidity, for demanding and accurate tests and processes Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-venticell-404-eco-lineMMM Friocell 222 - ECO line
The high technical standard of our FRIOCELL incubators allows tempering of samples, precise both in time and space. The unique cooling system offers an exact and cost saving simulation of the selected natural processes and reduces the samples evaporation. The incubators can be used in biotechnology, botany, zoology, food industry, cosmetics, chemical industry, etc. where it allows an extremely low duration of the temperature recovery. Inner volume: 55, 111, 222, 404, 707 and 1212 liters Working temperature: From 0.0°C up to 100°C Refrigerant: R 134a (R449a) Manual defrosting control Inner glass door Inner chamber: Stainless steel DIN 1.4301 (AISI 304) Technical data Inner dimensions - Chamber, stainless steel volume222 l depth520 mm width540 mm height760 mm Volume of the steam space 299 cca l Trays, stainless steel *) Min. distance between trays70 mm number10/2 max./usual Storage area (w × d)520 × 485 mm Number of outer metal doors number1 pcs Number of inner glass doors number1 pcs Admissible weight of trays together inside the oven70 kg per 1 tray30 kg Electricity data Max. power850 W Protective systemIP 20 mains 50/60Hz230 V Temperature data Cooling/down time from 22 °C to 10 °C< 17 min Heating/up time to 37 °C from the ambient temperature11 min Working temperature from 0,0 to100 °C Temperature accuracy - in time0,2 ± °C Temperature accuracy - in space at 10 °C0,5 ± °C Recovery time after 30 s door open at 37 °C2 min at 50 °C3 min Heat emission at 37 °C63 W Outer dimensions, incl. door and handle, Feet (N) or Rollers (K) depth900 mm width760 mm height1275 (N) mm Weight brut174 kg nett137 kg Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off. Precise, nature-adaptable, cost-saving – laboratory incubator 222-liter chamber volume Working temperature of from 0.0°C up to 100 °C Patented cooling system (ecological cooling medium R134a) offers a precise and quick simulation of natural processes and reduces the risk of samples evaporation; various types of the inner chamber lighting can be added to the unit High operation comfort; precise temperature regulation; possibility to reach even extremely short times of temperature changes and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door and possibility to regulate the fan speed Suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LCD display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-friocell-222-eco-lineMMM VENTICELL 707 - ECO line
Accurate and quick laboratory oven 707-liter chamber volume Working temperature of from +10°C over ambient temperature up to 250/300 °C Patented system of forced air flow in the chamber ensures a homogenous temperature profile for all processes of drying, heating and sterilizing materials in laboratories High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening Greater speed and accuracy of all tempering procedures ensures cost-saving operation; suitable especially for materials of high humidity, for demanding and accurate tests and processes Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ)
https://www.info-tek.com.tr/mmm-venticell-707-eco-lineMMM Friocell 404 - ECO line
The high technical standard of our FRIOCELL incubators allows tempering of samples, precise both in time and space. The unique cooling system offers an exact and cost saving simulation of the selected natural processes and reduces the samples evaporation. The incubators can be used in biotechnology, botany, zoology, food industry, cosmetics, chemical industry, etc. where it allows an extremely low duration of the temperature recovery. Inner volume: 55, 111, 222, 404, 707 and 1212 liters Working temperature: From 0.0°C up to 100°C Refrigerant: R 134a (R449a) Manual defrosting control Inner glass door Inner chamber: Stainless steel DIN 1.4301 (AISI 304) Precise, nature-adaptable, cost-saving – laboratory incubator 404-liter chamber volume Working temperature of from 0.0°C up to 100 °C Patented cooling system (ecological cooling medium R134a) offers a precise and quick simulation of natural processes and reduces the risk of samples evaporation; various types of the inner chamber lighting can be added to the unit High operation comfort; precise temperature regulation; possibility to reach even extremely short times of temperature changes and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door and possibility to regulate the fan speed Suitable for demanding and accurate tests and samples cultivation Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LCD display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility (IQ , OQ) Technical data Inner dimensions - Chamber, stainless steel volume404 l depth520 mm width540 mm height1415 mm Volume of the steam space 524 cca l Trays, stainless steel *) Min. distance between trays70 mm number19/2 max./usual Storage area (w × d)520 × 485 mm Number of outer metal doors number1 pcs Number of inner glass doors number1 pcs Admissible weight of trays together inside the oven100 kg per 1 tray30 kg Electricity data Max. power1700 W Protective systemIP 20 mains 50/60Hz230 V Temperature data Cooling/down time from 22 °C to 10 °C< 19 min Heating/up time to 37 °C from the ambient temperature22 min Working temperature from 0,0 to100 °C Temperature accuracy - in time0,3 ± °C Temperature accuracy - in space at 10 °C1 ± °C Recovery time after 30 s door open at 37 °C10 min at 50 °C13 min Heat emission at 37 °C123 W Outer dimensions, incl. door and handle, Feet (N) or Rollers (K) depth790 mm width1060 mm height1905 (K) mm Weight brut275 kg nett224 kg Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.
https://www.info-tek.com.tr/mmm-friocell-404-eco-line