• Örnek Mah. Ercüment Batanay Sk. No:14/E D:14 Zemin Kat Dumankaya İkon Ataşehir / İSTANBUL
  • +90 216 291 19 51
  • [javascript protected email address]

Arama Sonuçları..

Toplam 15 kayıt bulundu.
Polartronic® V – The Allrounder

Polartronic® V – The Allrounder

  Teknik Özellikler: Measurement scales °Optical rotation, °Specific rotation, °Z International Sugar Scale, % Concentration (g/mL, g/100mL, g/L) up to 1000 scales freely definable Measuring range ± 360° / ± 259°Z Resolution 0.001° / 0.01°Z Precision ± 0.005° / ± 0.015 °Z * Reproducibility ± 0.001° / ± 0.01 °Z Sensitivity  Up to OD 5 Wavelength  1 or 2 wavelengths fixed: 405, 435, 546, 578, 589, 633, 882 nm (others upon request) Response time ≤ 4 sec. over the entire measuring range Measuring tubes Different models, 10 to 200 mm length, Material: glass, stainless steel, acid-proof stainless steel, stainless-steel tubes with integrated temperature sensor*** Temperature measurement NTC sensor for measurement of sample temperature Range 0 °C – 99 °C Resolution 0.01 °C Precision ± 0.1 °C Light source LED, interference filter Display  7″ touchscreen, 800 x 480 pixel, 16 bit colors Operation Touchscreen, keyboard**, mouse**, barcode-reader**, remote via PC** Interface / Communication RS232 (1x), USB A (4x), USB B (1x), Ethernet (1x), LAN Conformity  International Pharmacopoeia, OIML, ASTM, ICUMSA, Australian Standard K157    

https://www.info-tek.com.tr/polaar-serisi-polarimetreler

Radleys Mya 4 Reaction Station

Radleys Mya 4 Reaction Station

A 4-zone reaction station offering safe and precise heating, active cooling,software control and data-logging for 24/7 unattended chemistry

https://www.info-tek.com.tr/mya-4-reaction-station

VariRef – Refractometer

VariRef – Refractometer

VariRef C VariRef B VariRef A Measuring scales Refractive Index (RI), Sucrose (% Brix)Standard scales included, freely definable scales Refractive Index (RI), Sucrose (% Brix), USG Measuring range 1.2900 – 1.5800 RI / 100% Brix 1.29000 – 1.58000 RI / 100% Brix1.32000 – 1.70000 RI / 100% Brix 1.320000 – 1.580000 RI / 100% Brix Precision ± 0.0001 RI* / ± 0.05% Brix* ± 0.00002 RI* / ± 0.02% Brix* ± 0.00002 RI / ± 0.02% Brix* Repeatability ± 0.0001 RI / ± 0.05% Brix ± 0.00002 RI / ± 0.02% Brix ± 0.000005 RI / ± 0.006% Brix Resolution 0.0001 RI / 0.05% Brix 0.00001 RI / 0.01% Brix 0.000001 RI / 0.001% Brix Ambient temperature + 10 °C to + 40 °C Temperature measurement NTC sensor Temperature range 5 °C to 80 °C 5 °C to 100 °C 20 °C (others upon request) Temperature precision / resolution ± 0.03 °C* / 0.01 °C Minimum sample volume 0,6 ml Temperature stabilization time 25 °C to 20 °C, ± 0.1 °C, in 1 minute (valid for ambient temp. = 20 °C) Measurement mode Single sample or flow through measurement (with optional compartment door) Prism Sapphire Sapphire / YAG Sapphire Light source / wavelength LED, interference filter 589 nm Display 7” Touchscreen**, 800 x 480 Pixel Operation Touchscreen**, Keyboard***, Mouse***, Barcode Reader***, Remote via PC / Tablet / Smartphone*** Interfaces Ethernet 10/100/1000, RS232, SH connector, USB, WLAN**, Modbus**, Canbus**, Profibus** Conformity International Pharmacopoeia, ASTM, AOAC, DIN, FDA, ICUMSA and others Power VAC 90-265; 50/60 Hz; 150 W max. Dimensions With display: 310 x 220 x 250 mm (w x d x h); without display: 310 x 220 x 150 mm (w x d x h) Highlights Modularity; user friendliness; fast temperature control; easy cleaning; variety of complete special sample room doors, e.g. for single or flow through measurements or for solid samples; the self-checking capabilities for cleanliness; environment temperature effects; calibration and more result in a virtually maintenance free product; 21 CFR Part 11 conform; ELN; LIMS ready

https://www.info-tek.com.tr/variref-refractometer

Coloromat® 100

Coloromat® 100

SPECIFICATIONS Coloromat 100 – V2 Optics Single beam photometer Wavelength range 340 – 900 nm* Pre-installed filters 560, 420, 720 nm FWHM 420 nm = 4 nm** 720 and 560 nm = 7 nm** Wavelength selection Via touch screen Light source LED Measuring range 0 – 16,000 ICUMSA Units (IU) Measuring accuracy ± 0.020 extinction at 420 nm ± 0.010 extinction at 560 nm ± 0.010 extinction at 720 nm ± 0.020 extinction at optional filters Resolution extinction 0.001 Resolution ICUMSA 1 IU Accuracy IU ± 10 % for colors < 20 IU ± 5 % for colors > 20 IU Operator Interface Touch screen for direct functions and alphanumerical inputs Data presentation Graphic display Data output RS232C & USB Operating temperature 10 – 40°C Languages English and German / Indonesian / Russian / Spanish   • Objective and repeatable measurements • 3 fixed wavelengths 340, 420 and 720 nm • Very narrow band width • 6 optional wavelengths (in the range of 340 - 900 nm)* • Automatic wavelength setting • Polarimeter cells up to 100 mm usable • Single or flow through measurements • Remote control via PC • Data output to PC or to directly connected printer, also via USB • Up to 250 methods programmable • GLP / GMP conform documentation • Largly maintenanee free   * For WL < 500 nm and > 700 nm, additional LED's may be required to ensure measurement accuracy and stability ** This very narrow half-value width enables high measurement accuracy as well as very good repeatability

https://www.info-tek.com.tr/coloromat-100

High-Res Process Refraktometre

High-Res Process Refraktometre

SCHMIDT + HAENSCH is proud to present the in-Line Process Refractometer High Resulution 2  model. This inline refractometer is perfect for all applications where a measuring needs to be as precise as laboratory testing. The iPR-HR2 is unrivaled in accuracy and can most certainly be claimed the world’s most precise process sensor. With a special water cooling system, the iPR-HR2 not only allows measuring in hot process environments and cleaning in place (CIP) – it also and ensures reliable measurements throughout its long product life span.  SPECIFICATIONS iPR HR 2 Measuring range 1 1.3200 - 1.3720 RI / 0 - 25 Brix Measuring range 2 1.4200 - 1.6000 RI / 50 - 100 Brix Resolution 0.000005 RI / 0.002 Brix Reproducibility ± 0.00004 RI / ± 0.02 Brix at 25°C ± 0.01 Brix up to 2% Process temperature -10°C up to + 100°C (with water cooling installed) Ambient temperature -10 - 45°C Pressure load capacity MPa (145 psi, 10 bar) - up to 30 bar available with APV conncection External power supply 20 V - 30 V DC ( at 24 V and 0.11 A) Interfaces 2 insulated 4 - 20 mA analog outputs 2 digital output switch (up to 1 A) 1 serial output (RS232, alternativly RS485 or USB) Power supply 24 V DC Prism Sapphire Light source / wavelength 589 nm LED Process contact material Sapphire, Stainless steel or Hastelloy Mounting accessories VariVent (Tuchenhagen), APV or TriClamp** * Standard conditions (589 nm, 20°C) ** Optional

https://www.info-tek.com.tr/high-res-process-refraktometre-2

Full Range Inline Process Refraktometre

Full Range Inline Process Refraktometre

SPECIFICATIONS iPR FR2 Measuring range 1 1.3200 - 1.5300 RI / 0-100 Brix Measuring range 2 1.4200 - 1.6000 RI / 50 - 100 Brix Resolution 0.00001 RI / 0.01 Brix Accuracy ±0.00007 RI / ± 0,05 Brix at 25° C Process temperature - 10°C to 150°C (with water cooling) Ambient temperature - 10° to + 45°C Pressure load capacity MPa (145 psi, 10 bar) - up to 30 bar available with APV conncection Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Interfaces 2 insulated 4 - 20 mA analog outputs 2 digital output switch (up to 1 A) 1 serial output (RS232, alternativly RS485 or USB) Power supply 24 V DC Prism Sapphire Light source / wavelength 589 nm LED Process pressure (max.) MPa (145 psi, 10 bar) Process contact material Sapphire, Stainless steel or Hastelloy Mounting accessories VariVent (Tuchenhagen), APV or TriClamp** * Standard conditions (589 nm, 20°C) ** Optional

https://www.info-tek.com.tr/full-range-inline-process-refraktometre-1

DIN EN ISO 11925-2 Single-Flame <b class=red>Source</b> Test (Ignitability Apparatus)

DIN EN ISO 11925-2 Single-Flame Source Test (Ignitability Apparatus)

DIN EN ISO 11925-2 Standardına uygundur yatay ve dikey kullanılabilen numune tutucu hassas hava hızı ayarlı entegre egzoz hava fanı cihazın ön tarafına kolay yakma kontrolü için yerleştirilmiş gaz basınç ayarlayıcı ve basınçölçer egzoz gaz akış hızını kontrol etmek için dijital anemometre standarda uygun zaman kayıt etmek için dijital kronometre 

https://www.info-tek.com.tr/din-en-iso-11925-2-single-flame-source-test-ignitability-apparatus

Saccharoflex 2020

Saccharoflex 2020

Specifications Saccharoflex 2020 Measuring scales Color grading of white crystal sugar acc. ICUMSA Measuring range 0 to 19.99 color units (CU) or derivative range Resolution 0.01 (CU) Precision ± 0.15 (CU) Reproducibility ± 0.15 (CU) Wavelengths 495 and 620 nm, tolerance 1%, mean waveband 20 nm Measuring time ≤ 1 sec Calibration Standards "0" to "6" of the Brunswick color type or ceramic standard Light source Tungsten halogen lamp 12 V, 20 W, base G4 Display LCD, one line, 16 characters, back illuminated Conformity ICUMSA method GS 2-13 (1998) Interfaces RS 232 C Dimensions 220 x 260 x 480 mm (w x d x h) Weight approx. 8,3 kg Highlights Precise and fast color type indication of white sugar crystals; reflectance factors at 495 and 620 nm are measured; measurement is done by use of the proven Taylor's law and an integrated sphere; great sample surface guarantees reliable measuring results; the instrument allows to measure also brown sugars due to the up to 19.99 CU extended measuring range; easy calibration by Brunswick color standards or longtime stable ceramic standards; the adjustable working voltage provides a high service life of the lighting unit

https://www.info-tek.com.tr/saccharoflex-2020

VariPol – Polarimeter

VariPol – Polarimeter

Teknik Özellikler:   Specifications VariPol C VariPol B Measurement scales ° Optical rotation, ° Specific rotation, °Z International Sugar Scale, % Concentration (g/mL, g/100mL, g/L),further scales freely definable Measuring range ± 89.9° Precision ± 0.01° * ± 0.005° * Repeatability ± 0.01° ± 0.005° Resolution 0.005° 0.001° Sensitivity Up to OD 3 Wavelength 1 or 2 wavelengths fixed, standard 589 nm, also available 365, 405, 436, 546 Measuring time 6 to 8 sec. over the entire measuring range Measuring tubes Up to 100 mm length; standard tubes, tubes with funnel or flow through; wetted parts: glass, stainless steel, Hastelloy Temperature measurement Pt1000 sensor (device) / NTC sensor (Quartz control plates and tubes) Sample temperature range 10 °C to 40 °C Temperature precision / resolution ± 0.1 °C* / 0.01 °C Peltier temp. regulation of the sample room 18 °C to 25 °C 10 °C to 40 °C Temperature stabilization time 25 °C to 20 °C, ± 0.1 °C, in 1 minute (valid for ambient temp. = 20 °C, with tube) Light source LED, interference filter Display 7” Touchscreen**, 800 x 480 Pixel Operation Touchscreen**, Keyboard***, Mouse***, Barcode Reader***, Remote via PC/Tablet/Smartphone*** Interfaces / Communication Ethernet 10/100/1000, RS232, USB, WLAN** Power VAC 90-265; 50/60 Hz; 150 W max Conformity International Pharmacopoeia, OIML, 21 CFR part 11, ICUMSA, Australian Standard K157 Dimensions With display: 430 x 300 x 270 mm (w x d x h); without display: 430 x 300 x 160 mm (w x d x h) Highlights Basic Polarimeter especially designed for pharmaceutical applications; Modularity; Fast measuring; Peltier system forautomatic temperature control; easy to calibrate; constant precision over the whole measuringrange, 21 CFR part 11ready; energy saving durable LEDs; ELN; LIMS ready  

https://www.info-tek.com.tr/aa-65-serisi-polarimetreler

ATR L Dispersion Refractometer

ATR L Dispersion Refractometer

SPESIFICATIONS ATR-L Measuring scales Refractive index (RI) Measuring range 1.33200 - 1.70000 RI* / 100% Brix Resolution 0.00001 RI* / 0.01 Brix Precision ± 0.00004 RI* / ± 0.03 Brix Reproductibility ± 0.00004 RI* / ± 0.03 Brix Measuring time per sample 20 sec for all 7 wavelength after temperature stabilisation; single sample measurement Ambient temperature + 15° to + 40°C Automatic temperature compensationOperational temperatureTemperature stabilityTemperature precision Solid state Peltier-thermostatisation+ 10°C to + 80°C0.01°C± 0.03°C Detector CCD-linear array with 2048 elements Sample compartment Used materials: stainless steel, Black Delrin®, Teflon®, Viton®, FFKM sealing Prism YAG Light source / Wavelength 7 discrete LED's with fixed wavelengths 400, 450, 490, 545, 590, 660, 700 nm (others on request),wavelength accuracy ± 2 nm Display LCD, 16 x 16 characters, back illuminated Operation 20 key membrane including function keys Interfaces /Communication 1 x RS232 C, 1x parallel, USB optional Standards                                                           European and international Pharmacopoeia, various ASTM, ISO and DIN standards Dimensions / Weight Mesuring head, stainless steel: 260 x 190 x 220 mm (w x h x d); control unit: 220 x 110 x 290 mm (w x h x d); complete unit 8 kg Highlights                                                                                                     Automatic dispersion measurement at 7 wavelengths over the full range of visibile light (intermediate values interpolated)**;Powerful, internal Peltier temperature control guarantees the fastest measurements with highest accuracy

https://www.info-tek.com.tr/atr-l-dispersion-refractometer

Case study: Rotary Evaporators at the University of Bristol

Case study: Rotary Evaporators at the University of Bristol

The outcome was that all 3 machines that had new seals replaced on the first day achieved an ultimate vacuum of 9 mbar.

https://www.info-tek.com.tr/university-of-bristol-rotary-evaporators

Saccharomat® V

Saccharomat® V

Measurement scales  °Z International Sugar Scale Measuring ranges – 35°Z to + 105°Z Resolution 0.01 °Z Precision ± 0.01 °Z Reproducibility ± 0.01 °Z Sensitivity Up to OD 5 Wavelength  1 or 2 wavelengths fixed: 587, 882 nm Response time ≤ 4 sec. over the entire measuring range Measuring tubes Different Models,  50, 100 or 200 mm length, Material: glass, stainless steel, acid-proof stainless steel, stainless steel tubes with integrated temperature sensor*** Temperature measurement NTC sensor for measurement of sample temperature Range 0 °C – 99 °C Resolution 0.01 °C Precision ± 0.1 °C Light source LED, interference filter Display  7″ TFT Touchscreen, 800 x 480 Pixel, 16 Bit colors Operation Touchscreen, keyboard**, mouse**, barcode reader**, remote via PC** Interface / Communication  RS232 (1x), USB A (4x), USB B (1x), Ethernet (1x), W-LAN/LAN** Conformity  International Pharmacopoea, OIML, ASTM, ICUMSA, Australian Standard K157  

https://www.info-tek.com.tr/saccharomat-v

ATR P

ATR P

SPECIFICATIONS ATR-P Measuring scales Refractive Index (RI), Sucrose (%Brix)Up to 1000 scales freely definable Measuring range 1.32000 - 1.54000 RI / 100% Brix Resolution 0.00001 RI / 0.01% Brix Precision ± 0,00002 RI / ± 0.02% Brix Reproducibility ± 0.00001 RI / ± 0.01% Brix Ambient temperature + 10° to + 40°C Automatic temperature compensation + 5° to + 50°C Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Temperature controlTemperature range Temperature control prism / sample by external water bath5°C / 50°C Measurement mode Single sample or flow through measurement / horizontal or vertical usage Prism Sapphire Light source / wavelength LED, interference filter 589 nm Display 7" Touchscreen, 800 x 480 Pixel, 16 Bit colors Operation Touchscreen, keyboard**, mouse**, barcode reader**, remote via PC** Interfaces 1 x RS232 C serial, 3 x USB (A), 1 x USB (B), 1 x Ethernet, Easy connection of keyboard, mouse, printer, barcode reader,PC and network Conformity International Pharmacopoea, ASTM, AOAC, DIN, FDA, ICUMSA and others Highlights Robust stainless steel measuring head for rough enviroments; High performance and accuracy; Continuous measurement;ESH¹ chamber; MBS² as stand alone with L-Display or polarimeter; Easy calibration; GLP/GMP;With theL-Display: Maintenancefriendlybyremotediagnostic; Intuitive userhandling guided OPsystem; Installationwizard;Full traceability of records; Ext. LIMS integration; Huge storage for 1000 products each with 1000 methods; 21 CFR part 11ready conformity³1 Easy sample handling; ² Modular build-in-system; 3 Optional software module for the L-Display Weight / dimensions Measuring Head: 4.5 kg; 200 x 160 x 135 mm (width x depth x height)L-Display: 3.0 kg; 240 x 190 x 150 mm (width x depth x height)

https://www.info-tek.com.tr/atr-p

ATR BR

ATR BR

SPECIFICATIONS ATR-BR Measuring scales Refractive Index (RI), Sucrose (%Brix), others on request Measuring range 1.32000 - 1.54000 RI / 100% Brix Resolution 0.00001 RI / 0.01% Brix Precision Measuring range 1.32 - 1.44: ± 0.00002 RI / ± 0.01% Brix *Measuring range 1.44 - 1.54: ± 0.00003 RI / ± 0.01% Brix * Reproducibility ± 0.00001 RI / ± 0.01% Brix Ambient temperature + 10° to + 40°C Automatic temperature compensation + 5° to + 50°C Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Technical control sample No control Measurement mode Single measurement Prism Sapphire Light source / wavelength LED, interference filter 589 nm Display Back-lit LCD, 16 x 16 characters Operation 20 key membrane including function keys Interfaces 1 x RS232 C serial and parallel Standard model ATR-BR Conformity International Pharmacopoea, ASTM, AOAC, DIN, FDA, ICUMSA and others Highlights Stand alone device; high quality and precision; very stable measurements: user friendly operation;excellent price performance ratio, very flat and small sample room for easy cleaning

https://www.info-tek.com.tr/atr-br

Single-Flame <b class=red>Source</b> Test (Ignitability Apparatus) EN ISO 11925-2

Single-Flame Source Test (Ignitability Apparatus) EN ISO 11925-2

FTT Ateşlenebilirlik Aparatının ana özellikleri şunlardır: Küçük önceden karıştırılmış alevin numuneye 45 ° açıyla eğilmesini ve bir akışkan hareketi ile sunulmasını sağlamak için, raylara monte edilmiş, geniş bir şekilde ayarlanabilen brülör tertibatı 60 mm kalınlığa kadar ve içinde örnekleri barındırabilen numune tutucu Tam olarak ayarlanmış bir numune destek çerçevesi, numune tutucunun yanal hareketini kolaylaştırır, böylece alev numune ortasındaki pozisyonda veya yanal aralıklı noktalarda uygulanabilir. Akış, sıcaklık ve zamanın basit ancak doğru ölçümü için dijital bir anemometre / termometre ve bir kronometre.

https://www.info-tek.com.tr/single-flame-source-test-ignitability-apparatus-en-iso-11925-2

-->
3WTURK CMS v6.0
-->