• Örnek Mah. Ercüment Batanay Sk. No:14/E D:14 Zemin Kat Dumankaya İkon Ataşehir / İSTANBUL
  • +90 216 291 19 51
  • [javascript protected email address]

Arama Sonuçları..

Toplam 42 kayıt bulundu.
Polartronic® V – The Allrounder

Polartronic® V – The Allrounder

  Teknik Özellikler: Measurement scales °Optical rotation, °Specific rotation, °Z International Sugar Scale, % Concentration (g/mL, g/100mL, g/L) up to 1000 scales freely definable Measuring range ± 360° / ± 259°Z Resolution 0.001° / 0.01°Z Precision ± 0.005° / ± 0.015 °Z * Reproducibility ± 0.001° / ± 0.01 °Z Sensitivity  Up to OD 5 Wavelength  1 or 2 wavelengths fixed: 405, 435, 546, 578, 589, 633, 882 nm (others upon request) Response time ≤ 4 sec. over the entire measuring range Measuring tubes Different models, 10 to 200 mm length, Material: glass, stainless steel, acid-proof stainless steel, stainless-steel tubes with integrated temperature sensor*** Temperature measurement NTC sensor for measurement of sample temperature Range 0 °C – 99 °C Resolution 0.01 °C Precision ± 0.1 °C Light source LED, interference filter Display  7″ touchscreen, 800 x 480 pixel, 16 bit colors Operation Touchscreen, keyboard**, mouse**, barcode-reader**, remote via PC** Interface / Communication RS232 (1x), USB A (4x), USB B (1x), Ethernet (1x), LAN Conformity  International Pharmacopoeia, OIML, ASTM, ICUMSA, Australian Standard K157    

https://www.info-tek.com.tr/polaar-serisi-polarimetreler

OLEUM

OLEUM

As a compact table top unit, the OLEUM centrifuge is used for oil test methods. Therefore, water content in the mineral oil is examinated. The OLEUM centrifuge comes with a four place swing out rotor which accomodates cushions for oil test tubes according to ASTM: Conical or Pearshaped form.

https://www.info-tek.com.tr/oleum

Ubbelohde Viscometer

Ubbelohde Viscometer

Ubbelohde Viscometers for automatic cleaning For automatic and stopwatch measurement. With screw connections and aspirating tube for permanent installation. Recommended for automatic cleaning with LAUDA VRM modules. • ISO 3105, DIN 51562, BS 188, NFT 60-100 • Filling volume: 18...22 ml • Total length: approx. 290 mm • Measurement accuracy: ±0.2 %

https://www.info-tek.com.tr/ubbelohde-viscometer-1

 ISO 4589-2, NES 714, <b class=red>ASTM</b> D2863, BS Oxygen Index (LOl)

ISO 4589-2, NES 714, ASTM D2863, BS Oxygen Index (LOl)

   ısıtma ve tüp ısıtma ile iki farklı ısıtma sistemi    400°C ’ ye kadar test imkanı    İki farklı ısılçift ile ısı ölçümü    Dijital göstergeli ve bağımsız ısı göstergeleri    Oksijen analizörü ,( %0-100 ölçüm aralığında ve %0.1     okuma hassasiyetinde)    Oksijen ve azot gazları için gaz kontrol ünitesi    çubuk şekilli ve düz numuneler için numune tutucuları    LOl yazılımı için tek lisans

https://www.info-tek.com.tr/iso-4589-2-nes-714-astm-d2863-bs-oxygen-index-lol

BS 6401, <b class=red>ASTM</b> E662, <b class=red>ASTM</b> F814, NFPA 258    NBS Smoke Density Chamber

BS 6401, ASTM E662, ASTM F814, NFPA 258 NBS Smoke Density Chamber

Numune yükleme ve oda temizliği için kolay erişim sağlayan, tam genişlikte açılır kapılı test odası. Kontroller uygun kullanım için odanın yanına monte edilir. Kapı açıkken tıkanmazlar. Duman yoğunluğu ve sıcaklık, daha kolay kullanım ve daha fazla hassasiyet için dijital ekranlardadır. Kolay çalıştırma ve uygun ekipman kullanımı için oda duvarları önceden ısıtılmıştır. Kolayca değiştirilebilen emniyet üflemeli panel, test yönteminin güvenli çalışmasını sağlar. İsteğe bağlı toksik gaz ölçümleri için gaz ölçüm noktaları sağlanmıştır. Gaz analizörlerinin ve harita kaydedicinin ve diğer kontrol ünitelerinin basit şekilde eklenmesi için standart 19 "rafa sahip kabin. İsteğe bağlı olarak mevcut bilgisayar yazılımı.

https://www.info-tek.com.tr/bs-6401-astm-e662-astm-f814-nfpa-258-nbs-smoke-density-chamber

ISO 5660, <b class=red>ASTM</b> E1354,  iCone® Plus Calorimeter

ISO 5660, ASTM E1354, iCone® Plus Calorimeter

Konik montaj pozisyonu için uzaktan kumanda, Testten önce numuneyi ısıya maruz bırakmaktan korumak için motorlu ısı kalkanının otomatik / manuel kontrolü Yanma gazlarını numuneden yakmak için kıvılcım ateşleyicisinin konumlandırılması ve kontrolü otomatik / manuel olarak kontrol edili 4 tarafı ısıya dayanıklı cam koruyucu ekranın otomatik / manuel kontrolü Numuneye bitişik 7 "renkli dokunmatik ekran test kontrol paneli İsteğe bağlı olarak temin edilebilen Karbon Dioksit ve Karbon Monoksit - NDIR gaz analizörleri Kontrollü Atmosfer Eklentisi İsteğe bağlı entegre duman dolabı Kütle Kaybı Kalorimetresi FTIR Toksisite Test Sistemi          

https://www.info-tek.com.tr/iso-5660-astm-e1354-icone-plus-calorimeter

The iCone²⁺ Calorimeter- ISO 5660; <b class=red>ASTM</b> E1354; <b class=red>ASTM</b> E1474; <b class=red>ASTM</b> E1740; <b class=red>ASTM</b> F1550; <b class=red>ASTM</b> D6113

The iCone²⁺ Calorimeter- ISO 5660; ASTM E1354; ASTM E1474; ASTM E1740; ASTM F1550; ASTM D6113

Ardışık 10 rampa veya tutma adımına kadar programlanabilir ısı akısına maruz kalma Testten önce numuneyi ısıya maruz bırakmaktan korumak için motorlu ısı kalkanının otomatik / manuel kontrolü Yanma gazlarını numuneden yakmak için kıvılcım ateşleyicisinin konumlandırılması ve kontrolü otomatik / manuel olarak kontrol edilir Yangın modeli etrafında cereyansız bir ortam sağlayan, her taraftan net görüntü sağlayan geri çekilebilir 4 tarafı ısıya dayanıklı cam koruyucu ekranın otomatik / manuel kontrolü Numuneye bitişik 4 "renkli dokunmatik ekran kontrol paneli ConeCalc Software tarafından gaz analiz cihazlarının ve tüm kalorimetrenin otomatik kalibrasyonu ve kontrolü 0.01g yük hücresi çözünürlüğü ve 8.2kg'a kadar yük kapasitesi Egzoz fanından titreşimi önlemek için bağımsız bir tablaya monte edilmiş hücre yükleyin Numune hazırlama ve temizleme için numune platformuna tamamen erişim Temizlemesi kolay, büyük ve oldukça dayanıklı siyah granit çalışma yüzeyi Yangın modeli koruma alarm sistemi FTT'den çevrimiçi destek ve enstrümanların uzaktan kontrolü

https://www.info-tek.com.tr/the-icone-calorimeter-iso-5660-astm-e1354-astm-e1474-astm-e1740-astm-f1550-astm-d6113-can-ulc-135-bs-476-part-15

VariRef – Refractometer

VariRef – Refractometer

VariRef C VariRef B VariRef A Measuring scales Refractive Index (RI), Sucrose (% Brix)Standard scales included, freely definable scales Refractive Index (RI), Sucrose (% Brix), USG Measuring range 1.2900 – 1.5800 RI / 100% Brix 1.29000 – 1.58000 RI / 100% Brix1.32000 – 1.70000 RI / 100% Brix 1.320000 – 1.580000 RI / 100% Brix Precision ± 0.0001 RI* / ± 0.05% Brix* ± 0.00002 RI* / ± 0.02% Brix* ± 0.00002 RI / ± 0.02% Brix* Repeatability ± 0.0001 RI / ± 0.05% Brix ± 0.00002 RI / ± 0.02% Brix ± 0.000005 RI / ± 0.006% Brix Resolution 0.0001 RI / 0.05% Brix 0.00001 RI / 0.01% Brix 0.000001 RI / 0.001% Brix Ambient temperature + 10 °C to + 40 °C Temperature measurement NTC sensor Temperature range 5 °C to 80 °C 5 °C to 100 °C 20 °C (others upon request) Temperature precision / resolution ± 0.03 °C* / 0.01 °C Minimum sample volume 0,6 ml Temperature stabilization time 25 °C to 20 °C, ± 0.1 °C, in 1 minute (valid for ambient temp. = 20 °C) Measurement mode Single sample or flow through measurement (with optional compartment door) Prism Sapphire Sapphire / YAG Sapphire Light source / wavelength LED, interference filter 589 nm Display 7” Touchscreen**, 800 x 480 Pixel Operation Touchscreen**, Keyboard***, Mouse***, Barcode Reader***, Remote via PC / Tablet / Smartphone*** Interfaces Ethernet 10/100/1000, RS232, SH connector, USB, WLAN**, Modbus**, Canbus**, Profibus** Conformity International Pharmacopoeia, ASTM, AOAC, DIN, FDA, ICUMSA and others Power VAC 90-265; 50/60 Hz; 150 W max. Dimensions With display: 310 x 220 x 250 mm (w x d x h); without display: 310 x 220 x 150 mm (w x d x h) Highlights Modularity; user friendliness; fast temperature control; easy cleaning; variety of complete special sample room doors, e.g. for single or flow through measurements or for solid samples; the self-checking capabilities for cleanliness; environment temperature effects; calibration and more result in a virtually maintenance free product; 21 CFR Part 11 conform; ELN; LIMS ready

https://www.info-tek.com.tr/variref-refractometer

VariDens

VariDens

Specifications VariDens C VariDens B Measuring range 0 – 3 g/cm3 Temperature range 10 – 95 °C* (regulated Peltier thermoelement) Pressure range 0 to 10 bar, (0 to 1 MPa) Density accuracy ± 0.0005 g/cm3 ± 0.00005 g/cm3 Resolution 0.0001 g/cm3 0.00001 g/cm3 Reproducibility ± 0.0002 g/cm3 ± 0.00002 g/cm3 Temperature accuracy ± 0.05 °C ± 0.03 °C Resolution 0.01 °C 0.001 °C Reproducibility ± 0.02 °C ± 0.01 °C Wetted parts Borosilicate glass, PTFE Bubble detection Yes (combined: visual-electronic) Drying Integrated air pump Temperature compensation Yes Minimum sample amount Approx. 1.5 ml Measuring time per sample** < 10 sec < 30 sec Display None or 7″ touchscreen, 800 x 480 Pixel Interfaces Ethernet 10/100/1000, RS232, SuH-Connector, USB, WLAN***, Modbus***, Canbus***, Profibus*** Ambient conditions Temperature 10 °C to 35 °C, Humidity < 85% not condensing Power supply VAC 90-265; 50/60 Hz; 150 maximum Dimensions With display: 310 x 220 x 235 mm (W x D x H) / without display: 310 x 220 x 150 mm (W x D x H) Standards International Pharmacopoeia, ASTM, AOAC, DIN, FDA, ICUMSA and others

https://www.info-tek.com.tr/varidens

Vizkozimetre Cihazları

Vizkozimetre Cihazları

• Polimer ve polimer türevlerinde kinematik olarak vikozimetre tayinidir.• Cihaz manuel, yarı otomatik ve tam otomatik olarak tayin yapabilececek sistemlere sahiptir.• Sistemler 100 0 C kadar polikarbonat banyo ve 300 0 C kadar dayanıklı metal gözlene bilir banyo ile ölçüm yapılır.• Sistemler software yardımıyla kontrol edilebilir.• Sistemlere opsiyonel olarak otomatik temizleme ünitesi ve otomatik örnekleyici üniteleri entegre edilebilir.• Sistemler ayrıca ASTM D 445 standartlarına uygun olarak madeni yağ ve türevlerinde ölçüm yapabilir.

https://www.info-tek.com.tr/vizkozimetre-cihazlari

<b class=red>ASTM</b> E162 - <b class=red>ASTM</b> D3675 Radiant Panel Flame Spread Apparatus

ASTM E162 - ASTM D3675 Radiant Panel Flame Spread Apparatus

Elektrikli kıvılcım ateşleyici ve otomatik emniyet alev dedektörü ile gözenekli çimento ve dökme demir gazlı radyan panel (12 "x 18") Alev cephesinin ilerlemesini değerlendirmek için her 3 "gözlem işaretine sahip paslanmaz çelik numune tutucu Paslanmaz çelik numune desteği Paslanmaz çelik pilot brülör montajı Parlak panelin yüzey sıcaklığını belirlemek için pirometre. Montaj dirseği dahil Karışımı radyan panele kontrol etmek için hava debimetre ve gaz kontrol vanası Termokuplların kolay temizlenmesini sağlamak için çıkarılabilir panelli paslanmaz çelik egzoz yığını Yığın standartların gerektirdiği 8 termokupl ile donatılmıştır. Metan gazı debimetreli kalibrasyon brülörü Emniyet gazı kontrolleri ve kesme devreleri

https://www.info-tek.com.tr/astm-e162-astm-d3675-radiant-panel-flame-spread-apparatus

ISO 5660, <b class=red>ASTM</b> E1354, iCone® Mini and iCone® Classic Calorimeters

ISO 5660, ASTM E1354, iCone® Mini and iCone® Classic Calorimeters

Programlanabilir ısı exposure ux pozlama. motorlu ısı kalkanı motorlu konumlandırma ve kıvılcım ateşleyicisinin kontrolü 4 taraflı ısıya dayanıklı cam koruyucu ekran El ile veya elektronik olarak kontrol edilen ısıya dayanıklı cam koruyucu ekran Numuneye bitişik 7 "renkli dokunmatik ekran test kontrol paneli ana bilgisayar kontrolünü destekler Yangın modeli koruma alarm sistemi İnternete bağlı sistem için FTT'den enstrümanların çevrimiçi desteği ve uzaktan kontrolü isteğe bağlı son test örneği N2 temizlenmiş duman dolabı  İsteğe bağlı olarak daha düşük ısı bırakma oranlarına sahip numuneleri test etmek için daha büyük Koni modeli.               

https://www.info-tek.com.tr/iso-5660-astm-e1354-icone-mini-and-icone-classic-calorimeters

FM 4910, <b class=red>ASTM</b> E2058, ISO 12136   Fire Propagation Apparatus

FM 4910, ASTM E2058, ISO 12136 Fire Propagation Apparatus

        FTT FPA  ;   Kritik ısı akışı Termal Tepki Parametresi (TRP), Etkili yanma ısısı , Kimyasal ve konvektif ısı yayılma oranları, Yangın Yayılma İndeksi (FPI)  Ortalama Korozyon İndeksi Duman verimi       belirlemek için kullanılır.  

https://www.info-tek.com.tr/fm-4910-astm-e2058-iso-12136-fire-propagation-apparatus

iCone mini Calorimeter- ISO 5660; <b class=red>ASTM</b> E1354; <b class=red>ASTM</b> E1474; <b class=red>ASTM</b> E1740; <b class=red>ASTM</b> F1550; <b class=red>ASTM</b> D6113

iCone mini Calorimeter- ISO 5660; ASTM E1354; ASTM E1474; ASTM E1740; ASTM F1550; ASTM D6113

Sıcaklık kontrolörü Motorlu Isı Kalkanı Kıvılcım Ateşlemesi Örnek Tutucular Örnek Paspayı Isıya Dayanıklı Cam Koruyucu Ekran Yük hücresi Gaz Örneklemesi Yanma Gazı Analizi Duman Gizleme Ölçümü Egzoz sistemi Isı Akısı Ölçer Kalibrasyon Brülörü Veri toplama ConeCalc Yazılımı - İngilizce, Fransızca, Almanca, İspanyolca ve Japonca dahil çoklu dilde mevcuttur. Kullanıcı arayüzü, "kullanıcı dostu" basma düğmeli işlemlere ve standart Windows veri giriş alanlarına, açılır seçicilere, onay kutularına ve anahtarlara sahip Windows tabanlı bir sistemdir: Control Cihaz kontrolü ve cihazın durumunu gösteren Analysis Gaz analiz cihazlarının kalibrasyonu ve kalibrasyon sonuçlarının depolanması Mass Kütle akış kontrol cihazının kullanılmasıyla C faktörü kalibrasyonu Fire Havuz ateşi (etanol) rutini ile C faktörü kalibrasyonu Test sırasında oluşturulan verilerin toplanması  

https://www.info-tek.com.tr/iconemini-calorimeter-iso-5660-astm-e1354-astm-e1474-astm-e1740-astm-f1550-astm-d6113-can-ulc-135-bs-476-part-15

Cam Viskozimetre Tüpleri

Cam Viskozimetre Tüpleri

Ubbelhode Viscometers: TypeCap. const. mm²/s²DIN/ASTM mm²/sPVS or iVisc mm²/sØ i mmCat. No. calibratedCat. No. uncalibrated 0c 0,003 0,7...3 0,3…2 0,47 EGV 700 EGV 709 0a 0,005 1…5 0,5…3 0,53 EGV 701 EGV 710 I 0,01 2…10 0,7...7 0,63 EGV 702 EGV 711 Ic 0,03 6…30 2…20 0,84 EGV 703 EGV 712 II 0,1 20…100 6…60 1,13 EGV 704 EGV 713 IIc 0,3 60…300 20…200 1,50 EGV 705 EGV 714 III 1 200…1.000 60…600 2,01 EGV 706 EGV 715 IIIc 3 600…3.000 200…2.000 2,65 EGV 707 EGV 716 IV 10 2.000…10.000 600…6.000 3,60 EGV 708 EGV 717 IVc 30 6.000…30.000 2.000…20.000 4,70 EGV 699 EGV 697   Micro-Ubbelhode Viscometers: TypeCap. const. mm²/s²DIN/ASTM mm²/sPVS or iVisc mm²/sØ i mmCat. No. calibratedCat. No. uncalibrated I 0,01 1…6 0,30…6 0,40 EGV 718 EGV 723 Ic 0,03 3…18 0,8…18 0,53 EGV 719 EGV 724 II 0,1 10…60 3…60 0,70 EGV 720 EGV 725 IIc 0,3 30…180 8…180 0,95 EGV 721 EGV 726 III 1 100…800 30…800 1,26 EGV 722 EGV 727   Ubbelohde Viscometers for automatic cleaning: TypeCap. const. mm²/s²DIN/ASTM mm²/sPVS or iVisc mm²/sØ i mm ±0,01Cat. No. calibratedCat. No. uncalibrated 0c 0,003 0,7...3 0,3…2 0,47 EGV 930 EGV 940 0a 0,005 1…5 0,5…3 0,53 EGV 931 EGV 941 I 0,01 2…10 0,7…7 0,63 EGV 932 EGV 942 Ic 0,03 6…30 2…20 0,84 EGV 933 EGV 943 II 0,1 20…100 6…60 1,13 EGV 934 EGV 944 IIc 0,3 60…300 20…200 1,50 EGV 935 EGV 945 III 1 200…1.000 60…600 2,01 EGV 936 EGV 946 IIIc 3 600…3.000 200…2.000 2,65 EGV 937 EGV 947 IV 10 2.000…10.000 600…6.000 3,60 EGV 938 EGV 948   Micro-Ostwald Viscometers: TypeCap. const. mm²/s²DIN/ASTM mm²/sPVS or iVisc mm²/sØ i mmCat. No. calibratedCat. No. uncalibrated I 0,01 1…6 0,30…6 0,43 EGV 820 EGV 825 Ic 0,03 3…18 0,8…18 0,60 EGV 821 EGV 826 II 0,1 10…60 3…60 0,77 EGV 822 EGV 827 IIc 0,3 30…180 8…180 1,00 EGV 823 EGV 828 III 1 100…800 30…800 1,36 EGV 824 EGV 829   Cannon-Fenske Routine Viscometers for automatic cleaning: TypeCap. const. mm²/s²DIN/ASTM mm²/sPVS or iVisc mm²/sØ i mmCat. No. calibratedCat. No. uncalibrated 50 0,004 0,8...4 0,4...3 0,44 EGV 951 EGV 986 75 0,008 1,6...8 0,8...6 0,54 EGV 952 EGV 987 100 0,015 3...15 2...10 0,63 EGV 953 EGV 988 150 0,035 7...35 4...25 0,78 EGV 954 EGV 989 200 0,1 20...100 8...60 1,01 EGV 955 EGV 990 300 0,25 50...250 20...100 1,27 EGV 956 EGV 991 350 0,5 100...500 40...200 1,52 EGV 957 EGV 992 400 1,2 240...1.200 100...500 1,92 EGV 958 EGV 993 450 2,5 500...2.500 200...1.000 2,35 EGV 959 EGV 994 500 8 1.600...8.000 700...3.500 3,20 EGV 960 EGV 995 600 20 4.000...20.000 1.500...7.500 4,20 EGV 961 EGV 996   Cannon-Fenske Routine Viscometers: TypeCap. const. mm²/s²DIN/ASTM mm²/sPVS or iVisc mm²/sØ i mmCat. No. calibratedCat. No. uncalibrated 50 0,004 0,8...4 0,4...3 0,44 EGV 861 EGV 873 75 0,008 1,6...8 0,8...6 0,54 EGV 862 EGV 874 100 0,015 3...15 2...10 0,63 EGV 863 EGV 875 150 0,035 7...35 4...25 0,78 EGV 864 EGV 876 200 0,1 20...100 8...60 1,01 EGV 865 EGV 877 300 0,25 50...250 20...100 1,27 EGV 866 EGV 878 350 0,5 100...500 40...200 1,52 EGV 867 EGV 879 400 1,2 240...1.200 100...500 1,92 EGV 868 EGV 880 450 2,5 500...2.500 200...1.000 2,35 EGV 869 EGV 881 500 8 1.600...8.000 700...3.500 3,20 EGV 870 EGV 882 600 20 4.000...20.000 1.500...7.500 4,20 EGV 871 EGV 883   Ubbelhode Dilution Viscometers: TypeCap. const. mm²/s²PVS or iVisc mm²/sØ i mmCat. No. calibratedCat. No. uncalibrated 0c 0,003 0,3…2 0,47 EGV 912 EGV 921 0a 0,005 0,5…3 0,53 EGV 913 EGV 922 0a 0,005 0,5…3 0,53 EGV 913-1* EGV 922-1* I 0,01 0,7...7 0,63 EGV 914 EGV 923 I 0,01 0,7...7 0,63 EGV 914-1* EGV 923-1* Ic 0,03 2…20 0,84 EGV 915 EGV 924 II 0,1 6…60 1,13 EGV 916 EGV 925            

https://www.info-tek.com.tr/cam-viskozimetre-tupleri

EN ISO 1716 Bomb Calorimeter

EN ISO 1716 Bomb Calorimeter

FTT Oksijen Bombası Kalorimetresi, çeşitli uygulamalardan üretilen ısının ölçülmesinde kullanılabilir ve mevcut ASTM, ISO, EN, BS ve DIN uluslararası standartlarına uyacak şekilde tasarlanmıştır.       Aşağıdaki malzeme gruplarının kalorifik değeri ölçülebilir:  Yapı malzemeleri (örneğin EN ISO 1716) Kömür, kok (örneğin, ASTM D 5865) Yakıt (benzin, gazyağı, akaryakıt, No. 1-D ve 2-D dizel yakıt ve No. 0-GT, 1-GT ve 2-GT gaz türbin yakıtları), (örneğin, ASTM D240-92) Hidrokarbon yakıtlar (örneğin, ASTM D 4809-90) Gıdalar, takviyeler, ürünler Atık ve çöp Yanıcı malzemeler vb.  

https://www.info-tek.com.tr/en-iso-1716-bomb-calorimeter

UL 94    - Horizontal/Vertical Flame Chamber

UL 94 - Horizontal/Vertical Flame Chamber

FTT UL 94, plastik malzemelerin tutuşabilirliğini cihaz ve cihazlardaki parçalar için test eder. büyük iç hacimi 1.0m3 olan ve iç ışık ve egzoz fanı ile donatılmış tezgah üstü taslaksız yanma odası Örnek tutucular Tamamen ayarlanabilir yatay ve dikey numune destekleri. Basit açı ayarlı (0 °, 20 °, 45 °) ve gaz debimetresi, basınç regülatörü ve manometre (manometre) de dahil olmak üzere hassas gaz kontrol sistemi ile ASTM D5025'e uygun bir brülör. Brülör ve numunenin hareketi için hazneye kolay giriş sağlayan iki erişim kapısı. Bir brülör kanat ucu. Doğru ancak basitleştirilmiş işlem için üç dijital test süresi sayacı        

https://www.info-tek.com.tr/ul-94-horizontalvertical-flame-chamber

<b class=red>ASTM</b> E 1678 - NFPA 269  Combustion Toxicity Test Apparatus

ASTM E 1678 - NFPA 269 Combustion Toxicity Test Apparatus

Örnek yönü yatay Numune montajlarını test etmek için uygun 200 litrelik polikarbonat haznesi Isı Akısı Ölçer Işınlama seviyeleri 10-50kW / m2 Kıvılcım ateşlemesi 500g numune kapasiteli yük hücresi Gaz analizörleri için 15 port

https://www.info-tek.com.tr/astm-e-1678-nfpa-269-combustion-toxicity-test-apparatus

iCone classic Calorimeter- ISO 5660; <b class=red>ASTM</b> E1354; <b class=red>ASTM</b> E1474; <b class=red>ASTM</b> E1740; <b class=red>ASTM</b> F1550; <b class=red>ASTM</b> D6113;

iCone classic Calorimeter- ISO 5660; ASTM E1354; ASTM E1474; ASTM E1740; ASTM F1550; ASTM D6113;

Sıcaklık kontrolörü Motorlu Isı Kalkanı Kıvılcım Ateşlemesi Örnek Tutucular Örnek Paspayı Isıya Dayanıklı Cam Koruyucu Ekran Yük hücresi Gaz Örneklemesi Yanma Gazı Analizi Duman Gizleme Ölçümü Egzoz sistemi Isı Akısı Ölçer Kalibrasyon Brülörü Veri toplama ConeCalc Yazılımı - İngilizce, Fransızca, Almanca, İspanyolca ve Japonca dahil çoklu dilde mevcuttur. Kullanıcı arayüzü, "kullanıcı dostu" basma düğmeli işlemlere ve standart Windows veri giriş alanlarına, açılır seçicilere, onay kutularına ve anahtarlara sahip Windows tabanlı bir sistemdir: Control Cihaz kontrolü ve cihazın durumunu gösteren Analysis Gaz analiz cihazlarının kalibrasyonu ve kalibrasyon sonuçlarının depolanması Mass Kütle akış kontrol cihazının kullanılmasıyla C faktörü kalibrasyonu Fire Havuz ateşi (etanol) rutini ile C faktörü kalibrasyonu Test sırasında oluşturulan verilerin toplanması Gerekli parametrelerin hesaplanması

https://www.info-tek.com.tr/iconeclassic-calorimeter-iso-5660-astm-e1354-astm-e1474-astm-e1740-astm-f1550-astm-d6113-can-ulc-135-bs-476-part-15

ATR L Dispersion Refractometer

ATR L Dispersion Refractometer

SPESIFICATIONS ATR-L Measuring scales Refractive index (RI) Measuring range 1.33200 - 1.70000 RI* / 100% Brix Resolution 0.00001 RI* / 0.01 Brix Precision ± 0.00004 RI* / ± 0.03 Brix Reproductibility ± 0.00004 RI* / ± 0.03 Brix Measuring time per sample 20 sec for all 7 wavelength after temperature stabilisation; single sample measurement Ambient temperature + 15° to + 40°C Automatic temperature compensationOperational temperatureTemperature stabilityTemperature precision Solid state Peltier-thermostatisation+ 10°C to + 80°C0.01°C± 0.03°C Detector CCD-linear array with 2048 elements Sample compartment Used materials: stainless steel, Black Delrin®, Teflon®, Viton®, FFKM sealing Prism YAG Light source / Wavelength 7 discrete LED's with fixed wavelengths 400, 450, 490, 545, 590, 660, 700 nm (others on request),wavelength accuracy ± 2 nm Display LCD, 16 x 16 characters, back illuminated Operation 20 key membrane including function keys Interfaces /Communication 1 x RS232 C, 1x parallel, USB optional Standards                                                           European and international Pharmacopoeia, various ASTM, ISO and DIN standards Dimensions / Weight Mesuring head, stainless steel: 260 x 190 x 220 mm (w x h x d); control unit: 220 x 110 x 290 mm (w x h x d); complete unit 8 kg Highlights                                                                                                     Automatic dispersion measurement at 7 wavelengths over the full range of visibile light (intermediate values interpolated)**;Powerful, internal Peltier temperature control guarantees the fastest measurements with highest accuracy

https://www.info-tek.com.tr/atr-l-dispersion-refractometer

<b class=red>ASTM</b> D 5485 - ISO 11907-4  Cone Corrosimeter

ASTM D 5485 - ISO 11907-4 Cone Corrosimeter

bir koni korrosimetresiyle kullanıldığında yanma ürünlerinin aşındırıcı etkisini belirlemek için kullanılabilir.

https://www.info-tek.com.tr/astm-d-5485-iso-11907-4-cone-corrosimeter

Saccharomat® V

Saccharomat® V

Measurement scales  °Z International Sugar Scale Measuring ranges – 35°Z to + 105°Z Resolution 0.01 °Z Precision ± 0.01 °Z Reproducibility ± 0.01 °Z Sensitivity Up to OD 5 Wavelength  1 or 2 wavelengths fixed: 587, 882 nm Response time ≤ 4 sec. over the entire measuring range Measuring tubes Different Models,  50, 100 or 200 mm length, Material: glass, stainless steel, acid-proof stainless steel, stainless steel tubes with integrated temperature sensor*** Temperature measurement NTC sensor for measurement of sample temperature Range 0 °C – 99 °C Resolution 0.01 °C Precision ± 0.1 °C Light source LED, interference filter Display  7″ TFT Touchscreen, 800 x 480 Pixel, 16 Bit colors Operation Touchscreen, keyboard**, mouse**, barcode reader**, remote via PC** Interface / Communication  RS232 (1x), USB A (4x), USB B (1x), Ethernet (1x), W-LAN/LAN** Conformity  International Pharmacopoea, OIML, ASTM, ICUMSA, Australian Standard K157  

https://www.info-tek.com.tr/saccharomat-v

ATR P

ATR P

SPECIFICATIONS ATR-P Measuring scales Refractive Index (RI), Sucrose (%Brix)Up to 1000 scales freely definable Measuring range 1.32000 - 1.54000 RI / 100% Brix Resolution 0.00001 RI / 0.01% Brix Precision ± 0,00002 RI / ± 0.02% Brix Reproducibility ± 0.00001 RI / ± 0.01% Brix Ambient temperature + 10° to + 40°C Automatic temperature compensation + 5° to + 50°C Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Temperature controlTemperature range Temperature control prism / sample by external water bath5°C / 50°C Measurement mode Single sample or flow through measurement / horizontal or vertical usage Prism Sapphire Light source / wavelength LED, interference filter 589 nm Display 7" Touchscreen, 800 x 480 Pixel, 16 Bit colors Operation Touchscreen, keyboard**, mouse**, barcode reader**, remote via PC** Interfaces 1 x RS232 C serial, 3 x USB (A), 1 x USB (B), 1 x Ethernet, Easy connection of keyboard, mouse, printer, barcode reader,PC and network Conformity International Pharmacopoea, ASTM, AOAC, DIN, FDA, ICUMSA and others Highlights Robust stainless steel measuring head for rough enviroments; High performance and accuracy; Continuous measurement;ESH¹ chamber; MBS² as stand alone with L-Display or polarimeter; Easy calibration; GLP/GMP;With theL-Display: Maintenancefriendlybyremotediagnostic; Intuitive userhandling guided OPsystem; Installationwizard;Full traceability of records; Ext. LIMS integration; Huge storage for 1000 products each with 1000 methods; 21 CFR part 11ready conformity³1 Easy sample handling; ² Modular build-in-system; 3 Optional software module for the L-Display Weight / dimensions Measuring Head: 4.5 kg; 200 x 160 x 135 mm (width x depth x height)L-Display: 3.0 kg; 240 x 190 x 150 mm (width x depth x height)

https://www.info-tek.com.tr/atr-p

ATR BR

ATR BR

SPECIFICATIONS ATR-BR Measuring scales Refractive Index (RI), Sucrose (%Brix), others on request Measuring range 1.32000 - 1.54000 RI / 100% Brix Resolution 0.00001 RI / 0.01% Brix Precision Measuring range 1.32 - 1.44: ± 0.00002 RI / ± 0.01% Brix *Measuring range 1.44 - 1.54: ± 0.00003 RI / ± 0.01% Brix * Reproducibility ± 0.00001 RI / ± 0.01% Brix Ambient temperature + 10° to + 40°C Automatic temperature compensation + 5° to + 50°C Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Technical control sample No control Measurement mode Single measurement Prism Sapphire Light source / wavelength LED, interference filter 589 nm Display Back-lit LCD, 16 x 16 characters Operation 20 key membrane including function keys Interfaces 1 x RS232 C serial and parallel Standard model ATR-BR Conformity International Pharmacopoea, ASTM, AOAC, DIN, FDA, ICUMSA and others Highlights Stand alone device; high quality and precision; very stable measurements: user friendly operation;excellent price performance ratio, very flat and small sample room for easy cleaning

https://www.info-tek.com.tr/atr-br

Pellet Press Dies | FTIR + XRF Dies

Pellet Press Dies | FTIR + XRF Dies

Ideal for producing high-quality pellets Evacuable for sample pellet clarity and quality Hardened Stainless Steel for durability Highly Polished Pellets Wide range of sizes and load capabilities Buy FTIR or XRF die

https://www.info-tek.com.tr/pellet-press-dies-ftir-xrf-dies

<b class=red>ASTM</b> E662, NBS Smoke Density Chamber

ASTM E662, NBS Smoke Density Chamber

       Genel Özellikler: Boyut (m): 1,90 (H) x 1,63 (L), x 0,66 (D) Güç Kaynağı: 110/230 V - 50/60 Hz - 13 A Gerçek oda boyutu: 914 mm × 914 mm × 610 mm

https://www.info-tek.com.tr/astm-e662-nbs-smoke-density-chamber

OSU Rate of Heat Release Apparatus- <b class=red>ASTM</b> E906 Standard

OSU Rate of Heat Release Apparatus- ASTM E906 Standard

Paslanmaz çelik yalıtımlı test odası, contalı kapı ve görüş penceresi Isı kaynağı olarak eşleşen set kızdırma çubuğu elemanları (korozyona dayanıklı paslanmaz çelik gövdeli) Isı akısı homojenlik ayarının kolaylığı için ikili globar güç kontrolörleri Üst pilot, kıvılcım ateşlemeli alt kalibrasyon ve metan gazı brülörleri ile kalibrasyon Bacada beş sıcak termokupl bağlantı ve hava odasındaki beş soğuk termokupl bağlantı ile ısı ölçümü için termopil Hava dağıtım sistemi ve egzoz yığını Numune tutucu, baskı plakası, montaj braketi ve damlama kabı ile Tekli kontrol ünitesi 19 inç rafa yerleştirilmiştir, şunlarla: - Radyant ısı kaynağı için tristör kontrolü - Brülörler için akış kontrolü - Hava besleme sistemi kontrolleri Kalibrasyon ısı akısı ölçer Yazılım, arayüz, bilgisayar ve lazer yazıcı

https://www.info-tek.com.tr/osu-rate-of-heat-release-apparatus-astm-e906-standard

Fire Propagation Apparatus -FM 4910; <b class=red>ASTM</b> E2058; ISO 12136

Fire Propagation Apparatus -FM 4910; ASTM E2058; ISO 12136

Global tarafından temiz oda ve kablo uygulamaları dahil olmak üzere çeşitli sigorta endüstrisi normları için yaygın olarak kullanılan bir araçtır. Metot ASTM tarafından ASTM E2058 olarak ISO ve ISO 12136 olarak standardize edilmiştir. FTT FPA şunları belirlemek için kullanılabilir: Kritik ısı akışı Termal Tepki Parametresi (TRP) Etkili yanma ısısı Kimyasal ve konvektif ısı yayılma oranları Yangın Yayılma İndeksi (FPI) Ayrıca aşağıdakileri ölçmek için de kullanılabilir: Ortalama Korozyon İndeksi Duman verimi

https://www.info-tek.com.tr/fire-propagation-apparatus-fm-4910-astm-e2058-iso-12136

NBS Smoke Density Chamber BS 6401; <b class=red>ASTM</b> E662; NFPA 258 Options: ISO 5659/IMO FTPC Part 2; ATS 1000.001/ABD0031; NES 711

NBS Smoke Density Chamber BS 6401; ASTM E662; NFPA 258 Options: ISO 5659/IMO FTPC Part 2; ATS 1000.001/ABD0031; NES 711

25 mm kalınlığa kadar olan temelde yassı bir numune, 25 kW / m² ya da kapalı bir odada, 25 kW / m²'lik bir radyan ısı kaynağına dikey olarak maruz kaldığında, malzemeler tarafından üretilen spesifik optik yoğunluğunu ölçer Tam genişlikte açılır kapılı test odası, numune yükleme ve hazne temizliği için kolay erişim sağlar Kontroller uygun kullanım için odanın yanına monte edilir. Kapı açıkken tıkanmazlar. Daha kolay kullanım ve daha fazla hassasiyet için duman yoğunluğu ve sıcaklık dijital göstergelerde Kolay çalıştırma ve uygun ekipman kullanımı için oda duvarları önceden ısıtılmıştır Kolayca değiştirilebilen emniyet üflemeli panel, test yönteminin güvenli çalışmasını sağlar İsteğe bağlı toksik gaz ölçümleri için gaz ölçüm portları sağlanmıştır  

https://www.info-tek.com.tr/nbs-smoke-density-chamber-bs-6401-astm-e662-nfpa-258-options-iso-5659imo-ftpc-part-2-ats-1000-001abd0031-nes-711

Density of Smoke from the Burning or Decomposition of Plastics <b class=red>ASTM</b> D2843

Density of Smoke from the Burning or Decomposition of Plastics ASTM D2843

ASTM D2843 Duman Yoğunluğu Testinin, kontrollü yanma veya ayrışma koşulları altında plastiklerin duman üretme özelliklerini ölçmek için kullanılması amaçlanmıştır. Ölçümler, kontrollü, standartlaştırılmış koşullar altında üretilen toplanmış bir duman hacminden ışık iletiminin kaybı açısından yapılır. Cihaz, test sırasında alev ve dumanın gözlenebileceği şekilde imal edilmiştir. Bu test, belirtilen koşullar altında basit, doğrudan ve anlamlı bir şekilde üretilen duman gizliliği miktarının ölçülmesini sağlar. Yanıcı maddeler tarafından üretilen dumanın görme engelini belirleme derecesi, büyüklük ve malzeme, nem, cereyan, sıcaklık ve oksijen kaynağı şeklindeki değişikliklerden etkilenebilir. Bir malzeme üzerinde yapılan bu testler, plastiklerin göreceli duman engelleme özelliklerinin karşılaştırılmasında önemli bir değer olabilir.

https://www.info-tek.com.tr/density-of-smoke-from-the-burning-or-decomposition-of-plastics-astm-d2843

LIFT, IMO Spread of Flame Apparatus ISO 5658-2; IMO Resolution A.653(16); <b class=red>ASTM</b> E1317; <b class=red>ASTM</b> E1321

LIFT, IMO Spread of Flame Apparatus ISO 5658-2; IMO Resolution A.653(16); ASTM E1317; ASTM E1321

Bu cihaz, bir test örneğini ateşlemek için pilot alevli ateşlemeli gazla çalışan radyant bir ısı paneli kullanır. Sonuçlar alev yayılma mesafesi / zaman geçmişi, alev ön hızı ile ısı akısına karşı, yangın söndürmedeki kritik ısı akışı ve sürekli yanma için ortalama ısı cinsinden ifade edilir. Cihaz gerekli tüm kontroller, akı metre ve numune tutucu ile birlikte verilir. Radyan brülör sistemi, kıvılcım ateşlemeli ve emniyet kilitli, tamamen otomatiktir.    

https://www.info-tek.com.tr/lift-imo-spread-of-flame-apparatus-iso-5658-2-imo-resolution-a-65316-astm-e1317-astm-e1321

Flooring Radiant Panel Test Apparatus EN ISO 9239-1; <b class=red>ASTM</b> E648

Flooring Radiant Panel Test Apparatus EN ISO 9239-1; ASTM E648

Bu test yöntemi, bir test odası içinde, dereceli bir radyant ısı ortamında, alevli bir ateşleme kaynağına maruz kalan yatay olarak monte edilmiş zemin kaplama sistemlerinin kritik radyant akışını ölçmek için kullanılır. Maruz kalan tavan arası selüloz yalıtımı için aynı kritik radyant akıyı ölçmek için de kullanılabilir. Özellikler: Kullanım kolaylığı için Açılı Kontrol Rafı, ekipman kurulumu ve kalibrasyonu sırasında aparat ve kontrollerin izlenmesini sağlar Radyan panelin otomatik olarak ateşlenmesi ve emniyet kesilmesi Gözetleme pencereli ve kayar platformlu 2 konumlu kapı ile test alanına menteşeli erişim Duman ölçüm portlu paslanmaz çelik başlık Veri toplama ve analiz yazılımı.  

https://www.info-tek.com.tr/flooring-radiant-panel-test-apparatus-en-iso-9239-1-astm-e648

Radiant Panel Flame Spread Apparatus <b class=red>ASTM</b> E162; <b class=red>ASTM</b> D3675

Radiant Panel Flame Spread Apparatus ASTM E162; ASTM D3675

Radyant Panel Alev Yayma Aparatı, gazla çalışan bir radyan ısı paneli kullanarak yapı ürünlerinin (ASTM E162) ve hücresel plastiklerin (ASTM D3675) yüzey yanıcılığını ölçer. Test sonucu, alev yayılımı ve ısı evrimi faktörlerinden belirlenen bir endekstir. Bu endeks, özellikle toplu taşıma sektörü (otobüsler ve trenler) için çeşitli spesifikasyonlarda gereklidir. Özellikler: Elektrikli kıvılcım ateşleyici ve otomatik emniyet alev dedektörü ile gözenekli çimento ve dökme demir gazlı radyan panel (12 "× 18") Alev cephesinin ilerlemesini değerlendirmek için her 3 "gözlem işaretine sahip paslanmaz çelik numune tutucu Paslanmaz çelik numune desteği Paslanmaz çelik pilot brülör montajı Parlak panelin yüzey sıcaklığını belirlemek için pirometre. Montaj dirseği dahil Karışımı radyan panele kontrol etmek için hava debimetre ve gaz kontrol vanası Termokuplların kolay temizlenmesini sağlamak için çıkarılabilir panelli paslanmaz çelik egzoz yığını Yığın standartların gerektirdiği 8 termokupl ile donatılmıştır. Metan gazı debimetreli kalibrasyon brülörü Emniyet gazı kontrolleri ve kesme devreleri

https://www.info-tek.com.tr/radiant-panel-flame-spread-apparatus-astm-e162-astm-d3675

Non-Combustibility Apparatus EN ISO 1182; IMO FTPC Part 1; <b class=red>ASTM</b> E2652

Non-Combustibility Apparatus EN ISO 1182; IMO FTPC Part 1; ASTM E2652

FTT, ısıtma işlemi sırasında ısıtıcı elemana çok yüksek bir akım beslemenin mümkün olduğu geleneksel varyasyon kontrolünün yerine, modern elektronikler kullanarak bu işlemi otomatikleştirmiştir. Bu sistemin, fırın ömrünü önemli ölçüde uzatan geleneksel değişken sistemler üzerindeki faydaları şunlardır: Yumuşak başlangıç Rampa hızı Güç sınırı Aşırı sıcaklık cihazı FTT ISO 1182 cihazı aşağıdakilerden oluşur: Özel Tüp Fırın, 19 "enstrüman kutusu, tüm enstrümantasyonları barındırır. Bu ünite, bir sıcaklık kontrol cihazı, bir aşırı sıcaklık alarmı ve fırın sıcaklığını 750 ° C'de kontrol eden, güç kaynağı voltaj dalgalanmalarını telafi eden ve gücün (Watt) olduğunu gösteren bir güç kontrol cihazı içerir. Yazılım (NonComb) Yazılım basit buton eylemleri, veri girişi alanları, onay kutuları ve diğer standart Windows işlemleri ile Microsoft Windows tabanlı bir uygulamadır. Operatör herhangi bir veri kaydetmeden bir test yapmadan önce Durum panelindeki sıcaklıkları izleyebilir. Testten önce, numune bilgileri (malzeme adı, yoğunluk, kütle, laboratuvar adı vb.) Bilgisayara girilir ve bir dosyaya kaydedilir.  Bir test sırasında, fırın sıcaklığı, numune yüzeyi ve numune merkezi termokuplları 2 Hz (yani her 0,5 saniyede bir) oranında ve gerçek zamanlı olarak bir grafikte gösterilen sıcaklıklar kaydedilir. Ayrıca, üç ısılçift tarafından kaydedilen ilk, maksimum ve son sıcaklıklar test çalıştırması sırasında görüntülenir. Testten sonra, kullanıcıdan malzeme performansı, toplam alevlenme süresi ve nihai kütle hakkında herhangi bir yorum girmesi istenir. Uygun sıcaklık artışları hesaplanır ve daha sonra test örneği için bir rapor oluşturulabilir. Test raporunda malzeme bilgileri, ilk, maksimum ve son sıcaklıklar, gerekli sıcaklık artışları, toplam yanma süresi, kütle kaybı (gerçek ve ilk kütlenin yüzdesi olarak) ve zamana göre kaydedilen sıcaklıkların bir grafiği gösterilmektedir. Test raporu ayrıca, uygun Standartlarda verilen başarılı başarısızlık kriterlerine referans içerir ve numunenin bu kriterleri karşılayıp karşılamadığını belirtir. Tüm test verileri sabit diske ASCII dosyası olarak kaydedilir; bu da ek analiz için elektronik tablolara aktarılabilir.    

https://www.info-tek.com.tr/non-combustibility-apparatus-en-iso-1182-imo-ftpc-part-1-astm-e2652

Oxygen Index <b class=red>ASTM</b> D2863; BS ISO 4589-2; NES 714

Oxygen Index ASTM D2863; BS ISO 4589-2; NES 714

Oksijen konsantrasyonu için dijital okuma: +/-% 0.1 Boyutlar (mm): 350 (W) × 370 (D) x 280 (H) Sütun boyutu (mm): 75 ve 95 (çap) × 450 (H) Ağırlık: 14 kg Gerilim: 230V 50Hz 1A veya 110V 60Hz 2A Kullanım Kılavuzu: Verilen Diğer Servis gereksinimleri: Şişelenmiş O2 / N2, Propan

https://www.info-tek.com.tr/oxygen-index-astm-d2863-bs-iso-4589-2-nes-714

Horizontal / Vertical Flame Chamber UL 94

Horizontal / Vertical Flame Chamber UL 94

FTT UL 94, plastik malzemelerin tutuşabilirliğini cihaz ve cihazlardaki parçalar için test eder   Özellikler: Yanma ürünlerinin basit bir şekilde tahliyesini sağlamak için büyük bir iç hacmi 1.0m³ olan ve bir iç ışık ve egzoz fanı ile donatılmış bir tezgah üstü taslaksız yanma odası Test sırasında numunenin cömert bir görüntüsünü sağlayan sertleştirilmiş güvenlik camından yapılmış büyük kapı ve pencere Örnek tutucular Tamamen ayarlanabilir yatay ve dikey numune destekleri Basit açı ayarlı (0 °, 20 °, 45 °) ve gaz debimetresi, basınç regülatörü ve basınç göstergesini içeren hassas gaz kontrol sistemi (ASTM D5025) ile uyumlu bir brülör. brülör ve numune Bir brülör kanadı ucu Doğru ancak basitleştirilmiş işlem için üç dijital test süresi sayacı

https://www.info-tek.com.tr/horizontal-vertical-flame-chamber-ul-94

FMVSS 302 FMVSS 302; ISO 3795; <b class=red>ASTM</b> D5132-04

FMVSS 302 FMVSS 302; ISO 3795; ASTM D5132-04

FTT FMVSS 302, 302 Federal Motorlu Taşıt Güvenliği Standardı uyarınca üretilmiştir. ISO 3795, Avrupa, Kanada ve Japonya'da kullanılan teknik olarak eşdeğer bir standarttır; ABD'de ASTM D5132-04 kullanılır. FMVSS 302, motorlu taşıtların yolcu bölümlerinde (yani binek araçları, çok amaçlı binek araçları, kamyonlar ve otobüsler) kullanılan malzemeler için yanmaya karşı direnç gereksinimlerini belirler. Bu, araç yangınlarından kaynaklanan motorlu taşıt yolcularına, özellikle de aracın içinde meydana gelenlere, eşleşme veya sigara gibi kaynaklardan kaynaklanan ölüm ve yaralanmaları azaltmaktır.

https://www.info-tek.com.tr/fmvss-302-fmvss-302-iso-3795-astm-d5132-04

Large Scale Hydraulic Tilting Fire Resistance Test Furnace for Vertical &amp; Horizontal Test Specimens  BS EN1364 (1-2); BS EN1365 (1-4); BS EN1366 (1-3); BS EN1634-1; <b class=red>ASTM</b> E119; <b class=red>ASTM</b> E814; <b class=red>ASTM</b> E1966;

Large Scale Hydraulic Tilting Fire Resistance Test Furnace for Vertical & Horizontal Test Specimens BS EN1364 (1-2); BS EN1365 (1-4); BS EN1366 (1-3); BS EN1634-1; ASTM E119; ASTM E814; ASTM E1966;

3000mm (W) × 4000mm (H) × 1000mm (D) boyutlarında iç hazneli Yangın Dayanımı Test Fırını Ismarlama kısıtlama çerçevelerine monte edilmiş dikey ve yatay test numuneleri üzerinde test yapabilme özelliği sağlar. Fırının, duvarlar ve kapılar gibi öğeleri test etmek için dik olarak veya zemin ve tavanları test etmek için yatay bir düzlemde konumlandırılmasını sağlamak için bir Hidrolik Devirme Sistemi sağlanmıştır.  

https://www.info-tek.com.tr/large-scale-hydraulic-tilting-fire-resistance-test-furnace-for-vertical-horizontal-test-specimens-bs-en1364-1-2-bs-en1365-1-4-bs-en1366-1-3-bs-en1634-1-astm-e119-astm-e814-astm-e1966

Furniture Calorimeter ISO 9705; <b class=red>ASTM</b> D5424; <b class=red>ASTM</b> D5537; <b class=red>ASTM</b> E603; <b class=red>ASTM</b> E1537; <b class=red>ASTM</b> E1590; <b class=red>ASTM</b> E1822; NFPA 265; UL 1685; NT FIRE 25; NT FIRE 32

Furniture Calorimeter ISO 9705; ASTM D5424; ASTM D5537; ASTM E603; ASTM E1537; ASTM E1590; ASTM E1822; NFPA 265; UL 1685; NT FIRE 25; NT FIRE 32

Büyük Ölçekli Oksijen Tüketimi Kalorimetrisi FTT, Mobilya Kalorimetresini uygun enstrümantasyon paketi ile birlikte hazırlar veya tedarik eder veya mevcut tesisleri geliştirmek isteyen veya kendi cihazlarını kurmak isteyen müşterilere enstrümantasyon sağlar.

https://www.info-tek.com.tr/furniture-calorimeter-iso-9705-astm-d5424-astm-d5537-astm-e603-astm-e1537-astm-e1590-astm-e1822-nfpa-265-ul-1685-nt-fire-25-nt-fire-32


Combustion Toxicity Test Apparatus <b class=red>ASTM</b> E1678; NFPA 269

Combustion Toxicity Test Apparatus ASTM E1678; NFPA 269

Ana Özellikler: Numune montajlarını test etmek için uygun Örnek yönü yatay 200 litrelik polikarbonat haznesi Isı Akısı Ölçer Işınlama seviyeleri 10-50kW / m² Kıvılcım ateşlemesi 500g numune kapasiteli yük hücresi Gaz analizörleri için 15 port Tedarik gereksinimleri: Gerilim: 230V - 50 / 60Hz - 40A Su: Soğutma aparatı için Boyutlar (mm): 1600 (H) × 1200 (W) × 480 (D) Ağırlık: 105 kg

https://www.info-tek.com.tr/combustion-toxicity-test-apparatus-astm-e1678-nfpa-269

Horizontal Fire Resistance Test Furnace BS 476 (20-24); BS EN 1363 (1-2); BS EN 1364 (2); BS EN 1365 (2-4); BS EN 1366 (1-3); <b class=red>ASTM</b> E119; <b class=red>ASTM</b> E814; <b class=red>ASTM</b> E1966; UL 263; UL 1709; UL 1479; UL 2079; UL10 (B-C); ISO 834 (1, 5-7, 9); ISO 6944 (1-2); ISO 3008

Horizontal Fire Resistance Test Furnace BS 476 (20-24); BS EN 1363 (1-2); BS EN 1364 (2); BS EN 1365 (2-4); BS EN 1366 (1-3); ASTM E119; ASTM E814; ASTM E1966; UL 263; UL 1709; UL 1479; UL 2079; UL10 (B-C); ISO 834 (1, 5-7, 9); ISO 6944 (1-2); ISO 3008

FTT Yatay Yangına Dayanım Test Fırını, bir düzeneğin parçasını oluşturan bir malzemenin yangına dayanıklılığı, düzenlemelere dayanan yapı elemanlarının performansını değerlendirmede çok değerli bir araçtır.   Yatay bir yapı tertibatının, kolonun veya desteğin yangına dayanıklılığını değerlendirmek için gerekli olan cihazdır ve bir malzemenin yatay yönde yüksek sıcaklıklara maruz kalmaya karşı dayanıklılığını ölçmek için bir yöntem sağlar. .

https://www.info-tek.com.tr/horizontal-fire-resistance-test-furnace-bs-476-20-24-bs-en-1363-1-2-bs-en-1364-2-bs-en-1365-2-4-bs-en-1366-1-3-astm-e119-astm-e814-astm-e1966-ul-263-ul-1709-ul-1479-ul-2079-ul10-b-c-iso-834-1-5-7-9-iso-6944-1-2-iso-3008

-->
3WTURK CMS v6.0
-->