Polartronic® V – The Allrounder

Polartronic® V – The Allrounder

  Teknik Özellikler: Measurement scales °Optical rotation, °Specific rotation, °Z International Sugar Scale, % Concentration (g/mL, g/100mL, g/L) up to 1000 scales freely definable Measuring range ± 360° / ± 259°Z Resolution 0.001° / 0.01°Z Precision ± 0.005° / ± 0.015 °Z * Reproducibility ± 0.001° / ± 0.01 °Z Sensitivity  Up to OD 5 Wavelength  1 or 2 wavelengths fixed: 405, 435, 546, 578, 589, 633, 882 nm (others upon request) Response time ≤ 4 sec. over the entire measuring range Measuring tubes Different models, 10 to 200 mm length, Material: glass, stainless steel, acid-proof stainless steel, stainless-steel tubes with integrated temperature sensor*** Temperature measurement NTC sensor for measurement of sample temperature Range 0 °C – 99 °C Resolution 0.01 °C Precision ± 0.1 °C Light source LED, interference filter Display  7″ touchscreen, 800 x 480 pixel, 16 bit colors Operation Touchscreen, keyboard**, mouse**, barcode-reader**, remote via PC** Interface / Communication RS232 (1x), USB A (4x), USB B (1x), Ethernet (1x), LAN Conformity  International Pharmacopoeia, OIML, ASTM, ICUMSA, Australian Standard K157    

https://www.info-tek.com.tr/polaar-serisi-polarimetreler

Hei-TORQUE Overhead Stirrers

Hei-TORQUE Overhead Stirrers

The powerful Hei-TORQUE series can accomplish the most demanding mixing tasks whilst providing the highest safety and increased operating lifetime. New Hei-TORQUE Core - the lightweight for big tasks! The compact design of the new Hei-TORQUE Core allows its use in closed systems such as fume hoods, reactors and production systems. With a net weight of 2.3 kg it is lightweight yet powerful enough to handle a variety of basic stirring applications with a maximum performance of 40 Ncm torque. The new Core model complements the Hei-Torque range of laboratory overhead stirrer series; providing an easy to use, entry level unit which has the same robustness and reliability from Heidolph.

https://www.info-tek.com.tr/hei-torque-overhead-stirrers

CA TB 603, CPSC 1633   Large <b class=red>Scale</b> Mattress Fire Test

CA TB 603, CPSC 1633 Large Scale Mattress Fire Test

FTT Koni Kalorimetresi ile rahatça çıkarılabilir ve kullanılabilir. Kanal bölümü, duman ölçüm ekipmanı (beyaz ışık veya lazer) ile birlikte gaz örneklemesi ve hava hızı ölçümü için problar içerir.

https://www.info-tek.com.tr/ca-tb-603-cpsc-1633-large-scale-mattress-fire-test

VariRef – Refractometer

VariRef – Refractometer

VariRef C VariRef B VariRef A Measuring scales Refractive Index (RI), Sucrose (% Brix)Standard scales included, freely definable scales Refractive Index (RI), Sucrose (% Brix), USG Measuring range 1.2900 – 1.5800 RI / 100% Brix 1.29000 – 1.58000 RI / 100% Brix1.32000 – 1.70000 RI / 100% Brix 1.320000 – 1.580000 RI / 100% Brix Precision ± 0.0001 RI* / ± 0.05% Brix* ± 0.00002 RI* / ± 0.02% Brix* ± 0.00002 RI / ± 0.02% Brix* Repeatability ± 0.0001 RI / ± 0.05% Brix ± 0.00002 RI / ± 0.02% Brix ± 0.000005 RI / ± 0.006% Brix Resolution 0.0001 RI / 0.05% Brix 0.00001 RI / 0.01% Brix 0.000001 RI / 0.001% Brix Ambient temperature + 10 °C to + 40 °C Temperature measurement NTC sensor Temperature range 5 °C to 80 °C 5 °C to 100 °C 20 °C (others upon request) Temperature precision / resolution ± 0.03 °C* / 0.01 °C Minimum sample volume 0,6 ml Temperature stabilization time 25 °C to 20 °C, ± 0.1 °C, in 1 minute (valid for ambient temp. = 20 °C) Measurement mode Single sample or flow through measurement (with optional compartment door) Prism Sapphire Sapphire / YAG Sapphire Light source / wavelength LED, interference filter 589 nm Display 7” Touchscreen**, 800 x 480 Pixel Operation Touchscreen**, Keyboard***, Mouse***, Barcode Reader***, Remote via PC / Tablet / Smartphone*** Interfaces Ethernet 10/100/1000, RS232, SH connector, USB, WLAN**, Modbus**, Canbus**, Profibus** Conformity International Pharmacopoeia, ASTM, AOAC, DIN, FDA, ICUMSA and others Power VAC 90-265; 50/60 Hz; 150 W max. Dimensions With display: 310 x 220 x 250 mm (w x d x h); without display: 310 x 220 x 150 mm (w x d x h) Highlights Modularity; user friendliness; fast temperature control; easy cleaning; variety of complete special sample room doors, e.g. for single or flow through measurements or for solid samples; the self-checking capabilities for cleanliness; environment temperature effects; calibration and more result in a virtually maintenance free product; 21 CFR Part 11 conform; ELN; LIMS ready

https://www.info-tek.com.tr/variref-refractometer

iCS EG

iCS EG

SPECIFICATIONS CONCENTRATION SENSOR Measuring scales Measuring scales upon request - specific to an individual application Process pressure max. 4 bar Operating temperature - 10 °C to + 50 °C Environmental temperature -40 °C to +65 °C Storage temperature -15 °C to 75 °C (recommended 5 °C - 35 °C, dry) Wetted parts Sapphire, stainless steel Interfaces RS485 (4 pin M8 plug) Power supply 12-28 VDC Current max. 30 mA (at 24 V) IP class IP67 Process pressure (max.) 100 kPa (14,5 psi, 1 bar), max. 4 bar Weight 220 g Diameter 40 mm (DN40), handle diameter 54 mm Engineering Engineering costs depend on application and installation - engineering costs beared by client Number of units purchase quantity is required

https://www.info-tek.com.tr/test

Compact InLine Proses Refraktometre

Compact InLine Proses Refraktometre

SPECIFICATIONS iPR C 2 Measuring scales Refractive Index (RI), Sucrose (Brix) (already included) Up to 4 scales freely definable Measuring range 1.3200 - 1.4209 RI / 0 - 50 Brix Resolution 0.0001 RI / 0.05 Brix Accuracy ± 0.0002 RI / ± 0.15 Brix at 25°C ATC range Brix +10 to +50°C Process temperature - 10° to + 65°C Process pressure max. 30 bar Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Interfaces 1 insulated 4 - 20 mA analog output 1 digital output switch (up to 1 A) 1 serial output (RS232, alternatively RS485 or USB) Power supply 24 V DC Prism Sapphire Data output 4 - 20 mA Process contact material Stainless steel or Hastelloy Dimension 150 mm x ø 65mm, approx. 1000g Mounting accessories VariVent (Tuchenhagen), APV or TriClamp** * Standard conditions (589 nm, 20°C) ** Optional

https://www.info-tek.com.tr/compact-inline-proses-refraktometre

DHR

DHR

SPECIFICATIONS DHR 95 Calibration Distilled Water Prism Material Optical Glass Sample Temperature 5 - 60 Degree Celsius Ambient Temperature 5 - 40 Degree Celsius Automatic Temperature Correction 5 - 70 Degree Celsius for 0 - 80 Brix Dimensions (LxWxD) 115 x 54 x 30 mm Weight 85 Grams (without Batteries fitted) Power 2xAAA Batteries Ratings & Compliance IP65 Dustproof/Water Resistant, CE, RoHS DHR 95 Key Features• 2 measurement scales:-Brix with Automatic Temperature Correction (ATC)-Refractive Index• 5-digit, full view LCD screen• Results displayed in 2 seconds• Holster Carrying Case Available as AccessoryTypical applications of the models• Agriculture• Veterinary• Industrial• Beverage• Food• Wine   Range of Models S+H model Scale Range Resolution Accuracy DHR 95 (Standard Model)Code number 16004 Sugar % (Brix)Refractive Index (RI) 0 ‐ 951.33 ‐ 1.54 0.10.0001 ± 0.2± 0.0003 DHR HoneyCode number 16009 Sugar % (Brix)Water in Honey % 0 ‐ 9510 ‐ 30 0.10.1 ± 0.2± 0.2 DHR WineCode number 16010 % Mass w/wAlcohol Probable (AP) 0 ‐ 350 ‐ 22 0.10.1 ± 0.2± 0.2 DHR OeCode number 16011 % Mass w/w° Oechsle 0 ‐ 3530 ‐ 130 0.11 ± 0.2± 1 DHR SalineCode number 16012 Sugar % (Brix)Saline (NaCl) 0 ‐ 540‐ 28 0.10.1 ± 0.2± 0.2 DHR AquaCode number 16013 Seawater PPT (Part Per Thousand)Seawater Specific Gravity (SG) 0 ‐ 1801.000 ‐ 1.070 10.0005 ± 1± 0.001 DHR VetCode number 16014 Urine Specific Gravity (SG) small mammalUrine Specific Gravity (SG) large mammal 1.000 ‐ 1.0501.000 ‐ 1.050 0.00050.0001 ± 0.001± 0.001 DHR PGCode number 16015 Propylene Glycol % by volumePropylene Glycol °C Protection 0 ‐ 600 to ‐ 50 0.11 ± 0.4± 1 DHR EGCode number 16016 Ethylene Glycol % by volumeEthylene Glycol °C Protection 0 ‐ 600 to ‐ 50 0.11 ± 0.4± 1 DHR DEFCode number 16017 % BrixFor measuring AdBlue© 0 ‐ 540 ‐ 40 0.10.1 ± 0.2± 0.2 - Further scales upon request!

https://www.info-tek.com.tr/dhr

Saccharoflex 2020

Saccharoflex 2020

Specifications Saccharoflex 2020 Measuring scales Color grading of white crystal sugar acc. ICUMSA Measuring range 0 to 19.99 color units (CU) or derivative range Resolution 0.01 (CU) Precision ± 0.15 (CU) Reproducibility ± 0.15 (CU) Wavelengths 495 and 620 nm, tolerance 1%, mean waveband 20 nm Measuring time ≤ 1 sec Calibration Standards "0" to "6" of the Brunswick color type or ceramic standard Light source Tungsten halogen lamp 12 V, 20 W, base G4 Display LCD, one line, 16 characters, back illuminated Conformity ICUMSA method GS 2-13 (1998) Interfaces RS 232 C Dimensions 220 x 260 x 480 mm (w x d x h) Weight approx. 8,3 kg Highlights Precise and fast color type indication of white sugar crystals; reflectance factors at 495 and 620 nm are measured; measurement is done by use of the proven Taylor's law and an integrated sphere; great sample surface guarantees reliable measuring results; the instrument allows to measure also brown sugars due to the up to 19.99 CU extended measuring range; easy calibration by Brunswick color standards or longtime stable ceramic standards; the adjustable working voltage provides a high service life of the lighting unit

https://www.info-tek.com.tr/saccharoflex-2020

VariPol – Polarimeter

VariPol – Polarimeter

Teknik Özellikler:   Specifications VariPol C VariPol B Measurement scales ° Optical rotation, ° Specific rotation, °Z International Sugar Scale, % Concentration (g/mL, g/100mL, g/L),further scales freely definable Measuring range ± 89.9° Precision ± 0.01° * ± 0.005° * Repeatability ± 0.01° ± 0.005° Resolution 0.005° 0.001° Sensitivity Up to OD 3 Wavelength 1 or 2 wavelengths fixed, standard 589 nm, also available 365, 405, 436, 546 Measuring time 6 to 8 sec. over the entire measuring range Measuring tubes Up to 100 mm length; standard tubes, tubes with funnel or flow through; wetted parts: glass, stainless steel, Hastelloy Temperature measurement Pt1000 sensor (device) / NTC sensor (Quartz control plates and tubes) Sample temperature range 10 °C to 40 °C Temperature precision / resolution ± 0.1 °C* / 0.01 °C Peltier temp. regulation of the sample room 18 °C to 25 °C 10 °C to 40 °C Temperature stabilization time 25 °C to 20 °C, ± 0.1 °C, in 1 minute (valid for ambient temp. = 20 °C, with tube) Light source LED, interference filter Display 7” Touchscreen**, 800 x 480 Pixel Operation Touchscreen**, Keyboard***, Mouse***, Barcode Reader***, Remote via PC/Tablet/Smartphone*** Interfaces / Communication Ethernet 10/100/1000, RS232, USB, WLAN** Power VAC 90-265; 50/60 Hz; 150 W max Conformity International Pharmacopoeia, OIML, 21 CFR part 11, ICUMSA, Australian Standard K157 Dimensions With display: 430 x 300 x 270 mm (w x d x h); without display: 430 x 300 x 160 mm (w x d x h) Highlights Basic Polarimeter especially designed for pharmaceutical applications; Modularity; Fast measuring; Peltier system forautomatic temperature control; easy to calibrate; constant precision over the whole measuringrange, 21 CFR part 11ready; energy saving durable LEDs; ELN; LIMS ready  

https://www.info-tek.com.tr/aa-65-serisi-polarimetreler

ATR L Dispersion Refractometer

ATR L Dispersion Refractometer

SPESIFICATIONS ATR-L Measuring scales Refractive index (RI) Measuring range 1.33200 - 1.70000 RI* / 100% Brix Resolution 0.00001 RI* / 0.01 Brix Precision ± 0.00004 RI* / ± 0.03 Brix Reproductibility ± 0.00004 RI* / ± 0.03 Brix Measuring time per sample 20 sec for all 7 wavelength after temperature stabilisation; single sample measurement Ambient temperature + 15° to + 40°C Automatic temperature compensationOperational temperatureTemperature stabilityTemperature precision Solid state Peltier-thermostatisation+ 10°C to + 80°C0.01°C± 0.03°C Detector CCD-linear array with 2048 elements Sample compartment Used materials: stainless steel, Black Delrin®, Teflon®, Viton®, FFKM sealing Prism YAG Light source / Wavelength 7 discrete LED's with fixed wavelengths 400, 450, 490, 545, 590, 660, 700 nm (others on request),wavelength accuracy ± 2 nm Display LCD, 16 x 16 characters, back illuminated Operation 20 key membrane including function keys Interfaces /Communication 1 x RS232 C, 1x parallel, USB optional Standards                                                           European and international Pharmacopoeia, various ASTM, ISO and DIN standards Dimensions / Weight Mesuring head, stainless steel: 260 x 190 x 220 mm (w x h x d); control unit: 220 x 110 x 290 mm (w x h x d); complete unit 8 kg Highlights                                                                                                     Automatic dispersion measurement at 7 wavelengths over the full range of visibile light (intermediate values interpolated)**;Powerful, internal Peltier temperature control guarantees the fastest measurements with highest accuracy

https://www.info-tek.com.tr/atr-l-dispersion-refractometer

Saccharomat® V

Saccharomat® V

Measurement scales  °Z International Sugar Scale Measuring ranges – 35°Z to + 105°Z Resolution 0.01 °Z Precision ± 0.01 °Z Reproducibility ± 0.01 °Z Sensitivity Up to OD 5 Wavelength  1 or 2 wavelengths fixed: 587, 882 nm Response time ≤ 4 sec. over the entire measuring range Measuring tubes Different Models,  50, 100 or 200 mm length, Material: glass, stainless steel, acid-proof stainless steel, stainless steel tubes with integrated temperature sensor*** Temperature measurement NTC sensor for measurement of sample temperature Range 0 °C – 99 °C Resolution 0.01 °C Precision ± 0.1 °C Light source LED, interference filter Display  7″ TFT Touchscreen, 800 x 480 Pixel, 16 Bit colors Operation Touchscreen, keyboard**, mouse**, barcode reader**, remote via PC** Interface / Communication  RS232 (1x), USB A (4x), USB B (1x), Ethernet (1x), W-LAN/LAN** Conformity  International Pharmacopoea, OIML, ASTM, ICUMSA, Australian Standard K157  

https://www.info-tek.com.tr/saccharomat-v

ATR P

ATR P

SPECIFICATIONS ATR-P Measuring scales Refractive Index (RI), Sucrose (%Brix)Up to 1000 scales freely definable Measuring range 1.32000 - 1.54000 RI / 100% Brix Resolution 0.00001 RI / 0.01% Brix Precision ± 0,00002 RI / ± 0.02% Brix Reproducibility ± 0.00001 RI / ± 0.01% Brix Ambient temperature + 10° to + 40°C Automatic temperature compensation + 5° to + 50°C Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Temperature controlTemperature range Temperature control prism / sample by external water bath5°C / 50°C Measurement mode Single sample or flow through measurement / horizontal or vertical usage Prism Sapphire Light source / wavelength LED, interference filter 589 nm Display 7" Touchscreen, 800 x 480 Pixel, 16 Bit colors Operation Touchscreen, keyboard**, mouse**, barcode reader**, remote via PC** Interfaces 1 x RS232 C serial, 3 x USB (A), 1 x USB (B), 1 x Ethernet, Easy connection of keyboard, mouse, printer, barcode reader,PC and network Conformity International Pharmacopoea, ASTM, AOAC, DIN, FDA, ICUMSA and others Highlights Robust stainless steel measuring head for rough enviroments; High performance and accuracy; Continuous measurement;ESH¹ chamber; MBS² as stand alone with L-Display or polarimeter; Easy calibration; GLP/GMP;With theL-Display: Maintenancefriendlybyremotediagnostic; Intuitive userhandling guided OPsystem; Installationwizard;Full traceability of records; Ext. LIMS integration; Huge storage for 1000 products each with 1000 methods; 21 CFR part 11ready conformity³1 Easy sample handling; ² Modular build-in-system; 3 Optional software module for the L-Display Weight / dimensions Measuring Head: 4.5 kg; 200 x 160 x 135 mm (width x depth x height)L-Display: 3.0 kg; 240 x 190 x 150 mm (width x depth x height)

https://www.info-tek.com.tr/atr-p

ATR BR

ATR BR

SPECIFICATIONS ATR-BR Measuring scales Refractive Index (RI), Sucrose (%Brix), others on request Measuring range 1.32000 - 1.54000 RI / 100% Brix Resolution 0.00001 RI / 0.01% Brix Precision Measuring range 1.32 - 1.44: ± 0.00002 RI / ± 0.01% Brix *Measuring range 1.44 - 1.54: ± 0.00003 RI / ± 0.01% Brix * Reproducibility ± 0.00001 RI / ± 0.01% Brix Ambient temperature + 10° to + 40°C Automatic temperature compensation + 5° to + 50°C Temperature measurement NTC sensor for measurement of sample temperature placed inside the prism Technical control sample No control Measurement mode Single measurement Prism Sapphire Light source / wavelength LED, interference filter 589 nm Display Back-lit LCD, 16 x 16 characters Operation 20 key membrane including function keys Interfaces 1 x RS232 C serial and parallel Standard model ATR-BR Conformity International Pharmacopoea, ASTM, AOAC, DIN, FDA, ICUMSA and others Highlights Stand alone device; high quality and precision; very stable measurements: user friendly operation;excellent price performance ratio, very flat and small sample room for easy cleaning

https://www.info-tek.com.tr/atr-br

Tissue Float Bath Order No 1052

Tissue Float Bath Order No 1052

Applications This special bath is preferably used for stretching and drying cut tissues in histological, pathological, chemical, clinical and bacteriological laboratories.

https://www.info-tek.com.tr/tissue-float-bath-order-no-1052

Large <b class=red>Scale</b> Mattress Fire Test CA TB 603; CPSC 1633

Large Scale Mattress Fire Test CA TB 603; CPSC 1633

Konsol, ısı tahliye oranlarını ve diğer ilgili parametreleri ölçmek için gerekli tüm enstrümantasyonları içerir. Bu enstrümantasyonun özellikleri hem büyük hem de küçük ölçekli kalorimetreler için aynıdır ve bu nedenle FTT Koni Kalorimetresi ile rahatça çıkarılabilir ve kullanılabilir. Kanal bölümü, duman ölçüm ekipmanı (beyaz ışık veya lazer) ile birlikte gaz örneklemesi ve hava hızı ölçümü için problar içerir.

https://www.info-tek.com.tr/large-scale-mattress-fire-test-ca-tb-603-cpsc-1633

Large <b class=red>Scale</b> Hydraulic Tilting Fire Resistance Test Furnace for Vertical &amp; Horizontal Test Specimens  BS EN1364 (1-2); BS EN1365 (1-4); BS EN1366 (1-3); BS EN1634-1; ASTM E119; ASTM E814; ASTM E1966;

Large Scale Hydraulic Tilting Fire Resistance Test Furnace for Vertical & Horizontal Test Specimens BS EN1364 (1-2); BS EN1365 (1-4); BS EN1366 (1-3); BS EN1634-1; ASTM E119; ASTM E814; ASTM E1966;

3000mm (W) × 4000mm (H) × 1000mm (D) boyutlarında iç hazneli Yangın Dayanımı Test Fırını Ismarlama kısıtlama çerçevelerine monte edilmiş dikey ve yatay test numuneleri üzerinde test yapabilme özelliği sağlar. Fırının, duvarlar ve kapılar gibi öğeleri test etmek için dik olarak veya zemin ve tavanları test etmek için yatay bir düzlemde konumlandırılmasını sağlamak için bir Hidrolik Devirme Sistemi sağlanmıştır.  

https://www.info-tek.com.tr/large-scale-hydraulic-tilting-fire-resistance-test-furnace-for-vertical-horizontal-test-specimens-bs-en1364-1-2-bs-en1365-1-4-bs-en1366-1-3-bs-en1634-1-astm-e119-astm-e814-astm-e1966


-->