Arama Sonuçları..
Toplam 4 kayıt bulundu.
DHR
SPECIFICATIONS DHR 95 Calibration Distilled Water Prism Material Optical Glass Sample Temperature 5 - 60 Degree Celsius Ambient Temperature 5 - 40 Degree Celsius Automatic Temperature Correction 5 - 70 Degree Celsius for 0 - 80 Brix Dimensions (LxWxD) 115 x 54 x 30 mm Weight 85 Grams (without Batteries fitted) Power 2xAAA Batteries Ratings & Compliance IP65 Dustproof/Water Resistant, CE, RoHS DHR 95 Key Features• 2 measurement scales:-Brix with Automatic Temperature Correction (ATC)-Refractive Index• 5-digit, full view LCD screen• Results displayed in 2 seconds• Holster Carrying Case Available as AccessoryTypical applications of the models• Agriculture• Veterinary• Industrial• Beverage• Food• Wine Range of Models S+H model Scale Range Resolution Accuracy DHR 95 (Standard Model)Code number 16004 Sugar % (Brix)Refractive Index (RI) 0 ‐ 951.33 ‐ 1.54 0.10.0001 ± 0.2± 0.0003 DHR HoneyCode number 16009 Sugar % (Brix)Water in Honey % 0 ‐ 9510 ‐ 30 0.10.1 ± 0.2± 0.2 DHR WineCode number 16010 % Mass w/wAlcohol Probable (AP) 0 ‐ 350 ‐ 22 0.10.1 ± 0.2± 0.2 DHR OeCode number 16011 % Mass w/w° Oechsle 0 ‐ 3530 ‐ 130 0.11 ± 0.2± 1 DHR SalineCode number 16012 Sugar % (Brix)Saline (NaCl) 0 ‐ 540‐ 28 0.10.1 ± 0.2± 0.2 DHR AquaCode number 16013 Seawater PPT (Part Per Thousand)Seawater Specific Gravity (SG) 0 ‐ 1801.000 ‐ 1.070 10.0005 ± 1± 0.001 DHR VetCode number 16014 Urine Specific Gravity (SG) small mammalUrine Specific Gravity (SG) large mammal 1.000 ‐ 1.0501.000 ‐ 1.050 0.00050.0001 ± 0.001± 0.001 DHR PGCode number 16015 Propylene Glycol % by volumePropylene Glycol °C Protection 0 ‐ 600 to ‐ 50 0.11 ± 0.4± 1 DHR EGCode number 16016 Ethylene Glycol % by volumeEthylene Glycol °C Protection 0 ‐ 600 to ‐ 50 0.11 ± 0.4± 1 DHR DEFCode number 16017 % BrixFor measuring AdBlue© 0 ‐ 540 ‐ 40 0.10.1 ± 0.2± 0.2 - Further scales upon request!
https://www.info-tek.com.tr/dhrCase study: Rotary Evaporators at the University of Bristol
The outcome was that all 3 machines that had new seals replaced on the first day achieved an ultimate vacuum of 9 mbar.
https://www.info-tek.com.tr/university-of-bristol-rotary-evaporatorsWater Still for single distillation Order No 2001/2
Applications GFL Water Stills are used in research and development e. g. for preparing bacteriological and medical samples, for cell and tissue cultures as well as for the production of reagents and unguents. Moreover, distillate is used for cleaning and sterilisation processes, for buffered solutions as well as microbiological and analytical applications.
https://www.info-tek.com.tr/water-still-for-single-distillation-order-no-20012Water Still for single distillation Order No 2001/4
Applications GFL Water Stills are used in research and development e. g. for preparing bacteriological and medical samples, for cell and tissue cultures as well as for the production of reagents and unguents. Moreover, distillate is used for cleaning and sterilisation processes, for buffered solutions as well as microbiological and analytical applications.
https://www.info-tek.com.tr/water-still-for-single-distillation-order-no-20014